Helios PD2-6400 High Voltage & High Current Meter
Instruction Manual
46
Factory Defaults & User Settings
The following table shows the factory setting for most
of the programmable parameters on the meter.
Factory Defaults & User Settings
Parameter
Display
Default Setting
Unit
units
Unit, channel A
Ch-A
Amp
Unit, channel V
Ch-V
Volt
Unit, channel P
Ch-P
Power
Number of points
No pts
Number of points, ch A
Ch-A
ddd.ddd
Number of points, ch V
Ch-V
ddddd.d
Number of points, ch P
Ch-p
ddddd.d
Scaling, (channel A)
Scal a
Input 1, channel A
InP 1
0.000
Display 1, channel A
Dis 1
0.000
Input 2, channel A
InP 2
5.000
Display 2, channel A
Dis 2
5.000
Scaling (channel V)
Scal V
Input 1, channel V
InP 1
0.000
Display 1, channel V
Dis 1
0.0
Input 2, channel V
InP 2
100.000
Display 2, channel V
Dis 2
100.0
Math, channel P
nmulti
Multiplication
Adder (constant C)
Adder
0.000
Factor (constant F)
Factor
1.000
Filter
Filter
Filter, channel A
Ch-A
70
Filter, channel V
Ch-V
70
Bypass, channel A
bypass
0.2
Bypass, channel V
bypass
0.2
Round
Round
1
Cutoff
Cutoff
Cutoff value, channel A
Ch-a
0.0 (disabled)
Cutoff value, channel V
Ch-V
0.0 (disabled)
Display assignment
Dsplay
Line 1
D Ch-V
Channel V
Line 2
d Ch-A
Channel A
Display intensity
d-Inty
6
Relay 1 assignment
Ch-V
Channel V
Relay 1 action
Act 1
Automatic
Relay 1 set point
Set 1
100.0
Relay 1 reset point
RSt 1
50.0
Relay 2 assignment
Ch-V
Channel V
Relay 2 action
Act 2
Automatic
Relay 2 set point
Set 2
200.0
Factory Defaults & User Settings
Parameter
Display
Default Setting
Relay 2 reset point
RSt 2
150.0
Relay 3 assignment
Ch-V
Channel V
Relay 3 action
Act 3
Automatic
Relay 3 set point
Set 3
300.0
Relay 3 reset point
RSt 3
250.0
Relay 4 assignment
Ch-V
Channel V
Relay 4 action
Act 4
Automatic
Relay 4 set point
Set 4
400.0
Relay 4 reset point
RSt 4
350.0
Fail-safe relay 1
Fls 1
Off
Fail-safe relay 2
Fls 2
Off
Fail-safe relay 3
Fls 3
Off
Fail-safe relay 4
Fls 4
Off
On delay relay 1
On 1
0.0 sec
Off delay relay 1
Off 1
0.0 sec
On delay relay 2
On 2
0.0 sec
Off delay relay 2
Off 2
0.0 sec
On delay relay 3
On 3
0.0 sec
Off delay relay 3
Off 3
0.0 sec
On delay relay 4
On 4
0.0 sec
Off delay relay 4
Off 4
0.0 sec
Current input break
relay 1
ignore
Ignore
Current input break
relay 2
ignore
Ignore
Current input break
relay 3
ignore
Ignore
Current input break
relay 4
ignore
Ignore
Display 1 analog out
Dis 1
0.0
Output 1 value
Out 1
4.000 mA
Display 2 analog out
Dis 2
200.0
Output 2 value
Out 2
20.000 mA
Source analog output
Source
Channel V
Overrange output
O-rang
21.000 mA
Underrange output
u-rang
3.000 mA
Current input break
output
break
3.000 mA
Maximum output
nmAx
23.000 mA
Minimum output
nmin
3.000 mA
Slave ID (Address)
SlaVId
247
Baud rate
baud
9600
Transmit delay
Tr dly
50 ms
Parity
Parity
Even
Byte-to-byte timeout
t-byt
010 (0.1 sec)