Helios PD2-6400 High Voltage & High Current Meter
Instruction Manual
25
Setting Numeric Values
The numeric values are set using the Right and Up
arrow buttons. Press Right arrow to select next digit
and Up arrow to increment digit value. The digit being
changed is displayed brighter than the rest. Press and
hold up arrow to auto-increment the display value.
Press the Enter button at any time to accept a setting
or Menu button to exit without saving changes.
Setting Up the Meter (
setup
)
The
Setup
menu is used to select:
1. Input signal the meter will accept for channel
A and channel V
2. Units for A, V, and P
3. Decimal point position for A, B, and C
4. Program the meter using the Scale or
Calibrate functions
5. Display parameter and intensity
6. Relay assignment and operation
7. 4-20 mA analog output scaling
Press the Menu button to exit at any time.
Setting the Decimal Point (
dEc pt
)
The decimal point may be set with up to five decimal
places or with no decimal point at all.
Pressing the Right arrow moves the decimal point one
place to the right until no decimal point is displayed,
and then it moves to the leftmost position.
There are three decimal points to set up for three
channels: Ch-A, Ch-V, and Ch-P.
After the decimal points are set up, the meter moves
to the
Program
menu.