15
Compact wall-mounted units KWL EC 500 W ET R/L
Installation and Operating Instructions
85297 001 SS-1042-1045 17.10.18
KWL EC ...
easyControls
1
8
1
6
1
4
LAN
Analog
Digital
supply
,
230V~
3 x 1,5mm²
L1
N
Optional: disconnector
pro
vided b
y customer/
On/off s
witch
DIN EN 60335-1 7.12.2
PE
signal of the saf
ety
de
vice
, see instr
uction
Optional: to be pro
vided
by the customer for room-air- dependent fireplaces !
2 m, 3 x 1,5mm²
Ether
net,
TCP/IP
,
- fix
ed installation with CA
T7 max.
75 m and
patch cabel with min.
CA
T5 max.
25 m in addition
100 Mbit/s
,
KWL-SL 6/3 (3 m and RJ12-Plug are included in the scope of supply) (5 m- SL6/5, 10 m- SL6/10, 20 m- SL6/20)
KWL-SL 4/3 (3 m and RJ10-Plug are included in the scope of supply) (5 m- SL4/5, 10 m- SL4/10, 20 m- SL4/20)
KWL-SL 4/3 to 4/20 resp
.
max.
length see tab
le
SS-1077
Helios-B
US
Slide s
witch controller
KWL-BE
Ar
t.Nr
. 4265
RJ12
1
2
3
1
6
S1
S2
S3
LAN-cab
le P
atch or Crosso
ver
KWL-BE, detailed plan see
SS-1071
1
6
1
6
KWL-BE
1
6
KWL-EC ...
WLAN-Router
Comf
or
t controller
KWL-BEC
Ar
t.Nr
. 4263
1
4
1
4
JP-J
umper
ter
minating resistor
open
plugged in
without ter
minating resistor
,
if not last B
US-par
ticipant
ter
minating resistor 120 Ohm
activ
e, if last par
ticipant at B
US
RJ10
JP
max.
8 pieces
KWL-BEC
, detailed plan see
SS-1072
1
4
KWL- components
KWL-EC ...
1
4
1
4
1
4
RJ10
JP
1
4
Extension module KWL-EM
Ar
t.Nr
. 4269
max.
2 pieces
KWL-EM, detailed plan f
or
- pr
inciple plan heating system
- electr
ic heater
, see
- w
ar
m w
ater heater resp
. L/SEWT see
Note addressing with DIP !
SS-1078
SS-1145
SS-1145
analog-control
1
4
1
4
1
4
RJ10
RJ10
RJ10
JP
JP
JP
1
4
1
4
1
4
1
of
f
on
2
DIP
DIP
DIP
DIP
1
of
f
on
2
3
4
1
of
f
on
2
3
4
1
of
f
on
2
3
4
Sensor KWL-CO
2
Ar
t.Nr
. 4272
Sensor KWL-FTF
Ar
t.Nr
. 4273
Sensor KWL-V
OC
Ar
t.Nr
. 4274
detailed plan
SS-1073
Note addressing with DIP !
detailed plan
SS-1074
detailed plan
SS-1075
max.
8 pieces
max.
8 pieces
max.
8 pieces
ex
emplar
y illustration !
Components can be equipped as required.
impor
tant notes
in the
BUS-Plan f
or components
and
SS-1077
SS-1079
KNX/EIB Modul KWL-KNX
Ar
t.Nr
. 4275
detailed plan
SS-1076
fix
ed inter
nal address
+24V
GND
A
B
1
4
2
3
+
-
120 Ohm ter
mination resistor
,
if last par
ticipant
supply
,
230V~
3 x 1,5mm²
1)
1)
1)
1)
1)
1)
2)
2)
KWL-SL flush-mounted Installation min.
placed in M25 pipe
.
cab
les f
or
LAN-Router
Inter
net
KWL-SL 6/3 to 6/20 resp
.
max.
length with e
.g.
LiYY 6x0,34mm² = 200 m
2)
Modb
us /
TCP/IP
Gatw
ay
Modb
us
3) protective conductor current of type 500 and 370 > 3,5 mA. External supply with 2 x PE or 1 x PE > 10 mm² according to EN 50178
3)
or
or
alter
nativ
e to KWL-BE:
GL
T-Signal 0-10
V to
RJ-12, Pin 2:
+ 0-10V
, Pin 3:
+4,6V(Offset=0), Pin 6:
GND
RJ-45
RJ-12
RJ-10
To be pro
vided b
y
customer
E
RJ
-4
5
RJ
-1
2
RJ
-1
0
P
IN
LA
N
A
na
lo
g
D
ig
ita
l
1
TX
+
+2
4,5
V / I
m
ax
0
,9
A
+2
4,5
V / I
m
ax
0
,9
A
2
TX
-
0
-
1
0 V fa
n l
eve
l
BU
S A
3
RX
+
3
,7
-
5
,5
V Offs
et
BU
S B
4
TC
LED
re
d
GN
D
5
RC
LED
g
re
en
x
6
RX
-
GN
D
x
7
fre
e
x
x
8
GN
D
x
x
5 .0 Standard connection plan SS-1045
Fig .46
CHAPTER 5
WIRING DIAGRAM
WIRING PLAN
EN