5.10. Text Message Alarm Notifications 

 

The Platinum Series Power Supply can send text message alarm 
notifications to a cell phone by sending the alarm e-mail to an 
address at the mobile phone provider. On the Network Setup

 

page, 

enter the address for your phone in one of the Recipient E-mail 
Addresses

 

field. For example, to send a text message to an AT&T 

phone, enter [email protected], replacing cell number

 

with your 

10-digit cell phone number. 

 

Here are some address formats for other mobile phone providers: 

 

AT&T 

cellnumber

@txt.att.net 

Verizon 

cellnumber

@vtext.com 

T-Mobile 

cellnumber

@tmomail.net 

Virgin Mobile 

cellnumber

@vmobl.com 

Nextel 

cellnumber

@messaging.nextel.com 

Bell Mobility 

cellnumber

@txt.bell.ca 

Rogers 

cellnumber

@pcs.rogers.com 

Telus 

cellnumber

@msg.telus.com 

Virgin Mobile (Can) 

cellnumber

@vmobile.ca 

 

5.11.  Network Troubleshooting 

 

I am unable to access the embedded Web server: 

 

  Check that you are using the correct IP address to access the 

power supply’s embedded Web server by viewing the Network 
Status

 

screen on the Control Panel display (see the Control 

Panel Menus section for instructions on how to access the 
Network Status screen). The IP address for the power supply 
may have changed if DHCP is enabled. 

 

 

If the Network Status

 

screen on the Control Panel display shows 

Network Not Connected, check the network cable connections to 
the power supply and the network. 

 

 

Ensure that you are using the correct type of network cable. An 
industry standard "crossover" cable should be used for 

Summary of Contents for ICT Platinum Series

Page 1: ...Instruction Manual 855 339 001 Australia sales heliosps com au Middle East Asia sales heliosps asia New Zealand sales heliosps co nz Your DC Power Solutions Partner...

Page 2: ...www heliosps com 2 Rev 1 0 Nov 2019...

Page 3: ...LEL OPERATION 23 4 1 SHARE Interface Connector 24 4 2 Configuring the Power Supplies for Parallel Operation 24 4 3 Connecting the Power Supplies in Parallel 25 4 4 Advanced Parallel Operation with TCP...

Page 4: ...rating for short circuit protection Ensure dc polarities and rated voltages are correct for both the load and battery connections to the unit Ensure all connections are properly tightened before power...

Page 5: ...Output voltage can be easily and accurately adjusted over standard battery operating voltage ranges using the Intelligent Power Control interface on the front panel Standard Ethernet port included for...

Page 6: ...input connector plug 3pin and 7 pin REMOTE connector plug DC output bus bar cover and mounting hardware installed Two Three with B option Bus bar bolts with locking nuts for output wiring Two rack mou...

Page 7: ...maximum battery charge current from the optional BAT port can be set independently from the main output current limit WARNING Potential for personal injury or damage to property and equipment due to...

Page 8: ...ht and secure using four standard rack nuts and bolts not provided After the unit is mounted connect the load battery and supply wiring as outlined in the steps below Refer to the back panel illustrat...

Page 9: ...n and disconnect device Otherwise damage to the unit load battery and personal injury may occur if the battery is inadvertently connected in reverse polarity or the output circuit is over loaded or sh...

Page 10: ...B LVD equipped models to pin 4 and 5 to automatically compensate the charging voltage according to the battery temperature Apply the probe body to the side of the middle battery case using the provid...

Page 11: ...e front of the Platinum Series power supply allows you to view the status of the unit and modify the power supply settings The Control Panel consists of the following Figure 2 Front Panel Display and...

Page 12: ...Use the Up Down keys on the Control Panel to scroll to the System Status screen and then press the Enter key The System Settings screen will appear 2 Using the Up Down keys scroll to the Output Voltag...

Page 13: ...wn keys change the DC output setting to On and then press the Enter key The DC output will now be enabled with the output voltage and current limit set as entered above 8 Press the Back key to return...

Page 14: ...link when the power supply is in current limit SYSTEM SETTINGS SCREEN From the System Status screen press Enter to move to the System Settings screen The System Settings screen allows you to modify th...

Page 15: ...talled These settings allow you to adjust the battery Low Voltage Disconnect LVD points configure the battery maximum charge current float voltage temperature compensation Equalize charge settings and...

Page 16: ...ttery Capacity Rating Ah Battery Discharge Rate Set the Battery discharge rate hrs used for capacity spec typically either 10 or 20hrs Low SOC Alarm Set the Low Battery State of Charge Alarm If the Ba...

Page 17: ...eature on any type of sealed battery Ensure the battery compartment is well ventilated to avoid any risk of explosion Do not exceed the Equalize voltage setting recommended by the battery manufacturer...

Page 18: ...Time limit as the battery was not able to power the load for the desired duration NOTE This test must only be done when AC power will be present during the test and for adequate time after the test t...

Page 19: ...the parallel settings PARALLEL SETTINGS SCREEN From the Parallel Status screen press Enter to move to the Parallel Settings Screen See the Smart Parallel Operation section for more information on conf...

Page 20: ...m date and time are normally set by the network These may be manually set see Network GUI Operation Communication Basic Setup section NETWORK STATUS SCREEN View the Network Status Screen to check the...

Page 21: ...see the Control Panel Menu Password Reset section for instructions on how to clear the password Set LCD Password Allows you to set the Control Panel menu password Clear LCD Password Allows you to cle...

Page 22: ...em Status screen is displayed on the Control Panel display 3 Release the Back and Enter keys You will no longer be prompted for a password on any of the Control Panel screens 4 In order to set a new p...

Page 23: ...se damage to equipment or connected load Up to six power supplies of the same output voltage rating can be connected in parallel to provide up to six times the total output power capability of a singl...

Page 24: ...lel Status screen and press Enter to move to the Parallel Settings screen 2 Scroll to the Parallel Mode setting and press Enter Scroll and choose a parallel mode setting then press Enter One unit must...

Page 25: ...ly measure the output voltage of each power supply with the load connected then adjust the output voltage level of each power supply using the Intelligent Power Control interface on the front of the P...

Page 26: ...SHARE B terminal on the second unit If there will be more than two units operating in parallel repeat this step for each unit as shown in Figure 4 above 5 Turn the Power Switch on all units to the ON...

Page 27: ...el Send Secondary Alarm Emails If this box is checked while this power supply is operating as Primary unit the Primary will send out alarm notification e mails when an alarm occurs on a Secondary unit...

Page 28: ...go to the Parallel Settings screen 5 Scroll to the Parallel Mode setting and press Enter Scroll and choose Standalone as the parallel mode setting then press Enter 6 The unit is now configured as a St...

Page 29: ...icrosoft Internet Explorer Mozilla Firefox or Google Chrome 1 Start your Web browser 2 Enter the IP address of the power supply in the location address field of the browser If the power supply is conn...

Page 30: ...30 3 Enter your user name and password The default Administrator user name is admin and there is no password by default 4 Once connected the System Status page will appear in your browser window...

Page 31: ...tes the output status of the power supply The output ON OFF buttons will enable or disable the DC output and optional battery LVD contactor The Auto Restart button will disable the supply output for t...

Page 32: ...rol tab to set all battery related parameters on units with the optional Battery LVD port SBC suffix units Click the Save Settings button after making changes to this page Output Voltage Control autom...

Page 33: ...lize voltage setting recommended by the battery manufacturer Always consult with battery manufacturer and observe all battery manufacturer recommendations Equalize Voltage Set the Equalize charge volt...

Page 34: ...nd time of the next Equalize charge if an Equalize Interval has been set Configure Battery The power supply will use this information to help determine the battery state of charge and remaining batter...

Page 35: ...never the Battery Over current Alarm is triggered Battery Low SOC Alarm Set the battery low state of charge alarm threshold and actions here SOC Threshold Set the battery low state of charge alarm thr...

Page 36: ...minutes for the Discharge Test Set Discharge Voltage Limit Set the minimum Discharge Voltage Limit If this Voltage Limit is hit before the Max Discharge Time limit the test will fail as the battery wa...

Page 37: ...configured correctly before any e mail notifications can be sent DC OUTPUT FAILURE ALARM The alarm latches the output off and clears when the DC output is manually re enabled Activate Alarm Form C Con...

Page 38: ...when an internal fan failure occurs and does not affect the power supply output state Activate Alarm Form C Contact If this box is checked the alarm form C contacts on the power supply will indicate...

Page 39: ...ondary unit alarm e mails if desired See section 4 4 Advanced Parallel Operation with TCP IP Ethernet Operation for more information Parallel Mode Select Stand alone Primary or Secondary mode here to...

Page 40: ...Click on the Download Log CSV button to store the CSV format log file on your computer for further analysis 5 5 Network Setup The NETWORK SETUP tab allows you to configure the network settings of the...

Page 41: ...er The default HTTP port is 80 If you change the HTTP port to a number other than 80 you will have to append the new port number to the URL used to access the power supply e g http 192 168 0 180 8000...

Page 42: ...o allow remote SNMP control of the power supply output If this box is unchecked all information available from the SNMP agent will be read only SNMP Contact Information Assign contact information such...

Page 43: ...es is capable of sending email alarm notifications to multiple email addresses Configure these settings on the EMAIL SETUP tab if you would like to receive e mail alarm notifications from the power su...

Page 44: ...f your SMTP server requires a user name and password enter the password here Leave this field blank if your SMTP server does not require authentication Minimum E mail Interval Specify a minimum interv...

Page 45: ...onfirm New Password When changing a password you must re enter the new password here to confirm Administrator Password Enter the current Administrator password here to confirm changes 5 8 Maintenance...

Page 46: ...his file Update the firmware on the power supply by clicking the Update Now button Do not remove AC power during the update process Send Test E Mail Pressing the Send Test E mail button will send test...

Page 47: ...urrent IP address of the power supply can be found on the Network Status screen see the Control Panel Menus section for more information e Check Enable and then click on Save Settings NOTE Many ISP s...

Page 48: ...ou may want to obtain a Static IP address from your ISP which will be more convenient to use to access the panel from a remote location A Static IP address is a fixed IP address that will not change A...

Page 49: ...umber messaging nextel com Bell Mobility cellnumber txt bell ca Rogers cellnumber pcs rogers com Telus cellnumber msg telus com Virgin Mobile Can cellnumber vmobile ca 5 11 Network Troubleshooting I a...

Page 50: ...t that the panel is connected to I am not receiving e mails from the power supply On the Communications Email Setup page ensure the SMTP Server field is the correct address for your e mail provider an...

Page 51: ...Offline A unit connected to the RS485 bus has lost power A RS485 data cable has been unplugged or damaged A communications reset has been done to a unit connected to the RS485 bus The alarm will be c...

Page 52: ...mperature Range 30 C to 70 C1 Storage Temperature 40 C to 70 C EMI Meets FCC part 15 and CE class B limits2 Safety Meets C UL EN 60950 1 standard Efficiency 90 93 typical Alarm Relay Form C 0 5A 125Va...

Page 53: ...it adjustment range 25 120A 13 60A 10 60A 5 30A 5 30A 2 5 15A Default Output Current Limit 120A 60A 60A 30A 30A 15A Output V Noise mV rms 30 30 30 30 60 60 Input Current max at 100Vin rms 18A 16A 120V...

Page 54: ...website at www ict power com support warranty repair The Purchaser shall at their own risk and cost return the defective product to ICT s factory or designated repair center once an RMA is issued by...

Page 55: ...nmental conditions such as rust corrosive atmospheres sustained temperatures outside the specified operating range of the equipment exposure to power surges and or electrical surges improper grounding...

Page 56: ...Helios Power Solutions Australia sales heliosps com au Middle East Asia sales heliosps asia New Zealand sales heliosps co nz...

Reviews: