KWL Hygrobox KWL HB.. EH/WW
Installation and Operating Instructions
5. Clean the water tank and UVC pipe
. In case of scale
deposits, clean with descaling agent and then rinse
thoroughly with water. In case of heavier contamination, it
makes sense to carry out descaling!
If descaling is carried out, this step can be omitted.
Ensure that no water drops on to the electronic
components. If necessary, cover these with
plastic film
6. During this work step, pay attention to leaking water!
Remove the supply hose from the hose connector on the
osmosis casing cover, pull out the reverse osmosis casing
and unscrew cover. Remove membrane from casing and
replace.
7.
Reassemble the device.
8.
Plug in the mains cable. Once plugged in, the water tank
is pumped out automatically.
9.
In case of scale deposits in the device and on the rotor,
the hardness of water must be increased by 1 – 2 steps in
the Expert menu.
10.
Maintenance is completed.
We are constantly striving to technically
improve and optimise our products and
we reserve the right to change versions
of the units or the technical data without
prior notice.
22. Subject to changes
21. Spare parts and Accessories
With regard to replacement
work and repairs, only original
spare parts may be used for
installation and application.
Safe operation is only ensured when
using original spare parts!
Name
Ref. no.
KWL-UVR
Water filter
5630
KWL-UVR
UVC pipe
5631
KWL-OME
Osmosis membrane
5632
KWL-PMA
Pump-mixer connection set (KWL HB 250 WW)
5629
KWL-PMA
Pump-mixer connection set (KWL HB 500 WW)
5634
KWL-NHR
Low-temperature aux. heater battery (KWL HB 250 WW)
5628
KWL-NHR
Low-temperature aux. heater battery (KWL HB 500 WW)
5633