Notes for removing faults
Fault
Remedy
The fan does not
start.
Check the fuses/trips at the main box and other connections.
Check the fan connection to the mains.
Check that fuses/trips in the connection box are correctly inserted.
The fan is noisy.
Check that all bolts and screws have been tightened.
Run in the fan and the bearings for 24 hours. Most noises disappear after
this time.
The fan vibrates
too much.
All blades have been weighed and grouped according to weight.
Their density can vary and therefore cause vibration even when all blades
are of the same weight. The following methods can contribute to preventing
most vibrations. Check the vibration before each procedure. Please note
that a small amount of vibration is normal and does not pose a problem.
Most vibrations occur when one of the blades is not in alignment with
the others. Aligning the blades is simply carried out with the aid of a flat
ruler. Place the ruler vertically upwards against the ceiling and alongside
the blade tip. Mark the distance between the blade side and ceiling.
Turn the blades slowly by hand and carry out the same measurements with
the other blades. If one of the blades is not correctly aligned, it can be
remedied by lightly pressing their holders upwards or downwards in order
to align them with the others.
Check that the mounting plate is firmly anchored to the ceiling.
Important:
Opening up and repairing the unit may only be carried out by a specialist!
15
Summary of Contents for DVW EC 130
Page 3: ...GB FR I D 14 14 14 14 a a a min 15 kg 3 ...
Page 4: ...GB FR I D 14 14 14 14 3 x 4 5 x 15 schwarz black noire nero 3 x 4 ...
Page 5: ...12 11 11 11 5 ...
Page 22: ...Klebegewicht Flügelklammer Flügel 22 ...
Page 23: ...Weigth Balde clip Blade 23 ...
Page 24: ...24 ...
Page 25: ...I 25 ...
Page 27: ...27 ...
Page 28: ... Helios Ventilatoren 1977 2017 Helios Ventilatoren AG Tannstr 4 CH 8112 Otelfingen 28 ...