1.9 Performance data
The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the
local supply network. The fan performances* were established on a test stand according to DIN EN ISO 5801.
1.10 Noise data
Noise data that refers to certain distances apply to free field conditions. With regard to installation, the sound
pressure level can differ significantly from the catalogue data, as it is highly dependent on the installation con-
ditions, i.e. on the absorption capability of the room and the room size among other factors.
2.0 Personnel qualification
m
The electrical connection and start-up as well as installation, servicing and maintenance of the fan
must only be carried out by qualified electricians.
– MiniVent
M1
/100/120
P
mini fans can be used by children over the age of 8 as well as persons with physical,
sensory, or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with
regard to the safe use of the unit and they understand the resulting risks. Children must not play with the unit.
Cleaning or user maintenance must not be carried out by unsupervised children.
2.1 Protection against contact
MiniVent
M1
/100/120
P
mini fans do not require a protection guard, as they meet the requirements of DIN
EN 60335-2-80 section 20.101.
2.2 Motor protection device
The motors of the MiniVent
M1
/100/120
P
are equipped with thermo contacts, which are wi-
red in series with the winding, and which automatically switch off and on again after cooling.
3.0 Type overview MiniVent M1/1.. F
M1
/100
P
equipped with two speeds and presence detector
M1
/120
P
equipped with two speeds and presence detector
3.1 Technical data
M1/100 P
Impeller Ø [mm]
92
Electrical supply line
NYM-O 3 x 1.5 mm²
Alternating current
1~
Protection category
IP 45 (water jet protection)
Voltage/frequency
230 V, 50 Hz
Protection class
II
Power consumption [W]
9/5
Weight approx. [kg]
0.8
Rated current [mA]
0.06/0.04
Speed [1/min]
2650/2250
Flow volume [m3/h]
90/75
M1/120 P
Impeller Ø [mm]
111
Electrical supply line
NYM-O 3 x 1.5 mm²
Alternating current
1~
Protection category
IP 45 (water jet protection)
Voltage/frequency
230 V, 50 Hz
Protection class
II
Power consumption [W]
13/10
Weight approx. [kg]
1.05
Rated current [mA]
0.09/0.08
Speed [1/min]
2350/2050
Flow volume [m3/h] 170/150