− The connection cable and the control line must be stored so that no water can get in along the cable in
case of water exposure. The cables must not be placed over sharp edges!
2. Drill holes:
Set casing against the wall, mark the holes and drill. Fasten with at least 2 screws and plugs.
3. Back draught shutter and guide van
− When installing the device, the guide vane must be mounted vertically (fig. 8).
− Snaps into place every 90° rotation.
− Affix the rubber foam (scope of delivery) before final assembly (fig.8)
fig.6
Ø 100 mm
Ø 120 mm*
r=58 mm
r=68 mm*
min. 90 mm
min. 90 mm
Cable exit
possible as
required in
dark area
drill holes
Recommen-
ded cable
exit optional
0...-360 °,
ideally 45°
*
Type M1/120..
min. 110 mm*
min. 110 mm*
fig.7
Cable routing under the casing. Cable
length from wall at least
180 mm.
À
fig.9
ê
Condensate drain holes for
ceiling suspension.
â
Break out entry
knockout for cable for
wall mounting
ô
Cable grommet
ô
â
ê
ê
fig.8
When installing the device, the
guide vane
ö
must be mounted
vertically (as depicted). Snaps into
place every 90° rotation
Guide vane
ö
removable
Back
draught
shutter
ü
removable
ö
Affix the
rub-
ber foam
vertical for wall installation
top
bottom
EN
MiniVent M1/
100/120
P
Installation and Operation Instructions
8