![Heinzmann Triton OMD Manual Download Page 33](http://html1.mh-extra.com/html/heinzmann/triton-omd/triton-omd_manual_2120037033.webp)
7
General
communication functions overview
Triton OMD CAN protocol / Rev.-No. 03
25
7.6.2
Error and status report
Error state and general status information is delivered to the master by means of telegram
kErrorStatusReport.
Data items within this telegram:
•
OMD Error Status;
•
Sensor Error State;
•
Sensor Output State.
No.
Indicated value
External value range Unit Internal value range
2680 -
2695
OMDError_Sensor1 –
OMDError_Sensor16
0 - FFFF
Hex 0 - FFFF
2700 -
2715
ErrorState_Sensor1 –
ErrorState _Sensor16
0 - FFFF
Hex
0 - FFFF
2720 -
2735
StatusInfo_Sensor1 –
StatusInfo_Sensor16
0 - FFFF
Hex
0 - FFFF
Tab. 7.4 Sensor error and status control parameters
Bit description for OMD error status report data items is provided in the tables below.
Bit Number.
Bit function
0
Broken Wire LERD
1
Broken Wire LRD C
2
Broken Wire LRD D
3
Error Scattered Connected
4
Dirty LERD A
5
Dirty LERD B
6
Primary Alarm
7
Pre-Alarm
8
Maintenance
9
free
10
free
11
free
12
free
13
free
14
Common Error
15
Fatal Error
Tab. 7.5 OMD-error status bits
Summary of Contents for Triton OMD
Page 2: ......
Page 8: ......
Page 12: ...2 System description 4 Triton OMD CAN protocol Rev No 03...
Page 16: ...3 HEINZMANN CAN protocol 8 Triton OMD CAN protocol Rev No 03...
Page 22: ...5 Send telegrams specification 14 Triton OMD CAN protocol Rev No 03...
Page 26: ...6 Receipt telegram specification 18 Triton OMD CAN protocol Rev No 03...