7
General
communication functions overview
Triton OMD CAN protocol / Rev.-No. 03
23
7.4.3
Configuration data memory layout
Both OMD devices, evaluator and sensor, use the same MCU type. For the cases when OMD
sensor is used with third party superordinate system instead of OMD evaluator, it is important
to consider configuration data memory layout of sensor device. This is critical for correct con-
figuration parameter set CRC calculation by superordinate system.
Configuration data memory layout features:
•
Little endian data format;
•
16-bit sized parameter data item;
•
2-byte parameter data alignment.
7.5
Sensor internal function execution request
Master can request internal function execution in all sensor-devices in the network by means
of telegram
kInternFunctionRequest
.
Data items within this telegram:
•
Internal function execution command.
Bit description for internal function execution command data item is provided in the tables
below.
Bit Number.
Bit function
0
Clear current errors
1
free
2
free
3
free
4
free
5
free
6
free
7
free
8
free
9
free
10
free
11
free
12
free
13
free
14
free
15
free
Tab. 7.2 Sensor internal function execution command
Summary of Contents for Triton OMD
Page 2: ......
Page 8: ......
Page 12: ...2 System description 4 Triton OMD CAN protocol Rev No 03...
Page 16: ...3 HEINZMANN CAN protocol 8 Triton OMD CAN protocol Rev No 03...
Page 22: ...5 Send telegrams specification 14 Triton OMD CAN protocol Rev No 03...
Page 26: ...6 Receipt telegram specification 18 Triton OMD CAN protocol Rev No 03...