![Heinzmann Triton CPM 500 Manual Download Page 21](http://html1.mh-extra.com/html/heinzmann/triton-cpm-500/triton-cpm-500_manual_2120033021.webp)
5 Visualisation software release 1.0.7.8
CPM 500 Electronic Peak Pressure Indicator
21
5.4.1.6
Automatic Pcomp calculation on four-strokes
During the first opening of measurement data file (*.ext) the Pmax value is centered at TDC (0°CA). For Pcomp
calculation on 4-stroke calculation the operator should press “Optimize” button.
Press “Optimize“
After pressing “Optimize“
please wait for calculation of
Pcomp of each cylinder.
Calculation time 5…8 s / cylinder