5 Visualisation software release 1.0.7.8
CPM 500 Electronic Peak Pressure Indicator
18
5.4.1.3
Save to ASCII
Press “ASCII-File” to save all measurement data to Excel (*.csv) files.
The software opened a window to store data to (*.csv) files.
5.4.1.4
Optimize function for application on two-strokes
IMES algorithm for automatic Pcomp position calculation on two-strokes can be influenced by some noises on
the pressure signal. If Pcomp Position is not exact centred on TDC position than please press button
“OPTIMIZE”
Remarks: Optimum Pcomp position influences also IPOWER and IMEP calculation for application with dongle
620-66-002-00!
1.
Check all curves
Some curves should be
checked for optimum
position of Pcomp !