background image

 

 

GASOLINE GENERATOR 

 

BEFORE OPERATING THIS MACHINE, 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. 

 

 

 
 
 

Thank you for choosing Heinner! 
 
WARNINGS: 
 

1.

 

Read the operator’s instruction 

manual. 

2.

 

Attention!  Exhaust  gases  are  toxic.  Do  not  operate  the  generator  in  a  room 
without ventilation system! 

3.

 

Children  should  be  protected  by  keeping  them  at  a  safe  distance  from  the 
generator set! 

4.

 

Refilling of the generating sets are not allowed during the operation! 

5.

 

If  the  generator  will  be  mounted  in  a  closed  room,  relevant  safety  regulations 
against fire and explosion should be followed! 

6.

 

Do not connect to household circuit! 

7.

 

Do not use in wet condition! 

8.

 

Keep away from flammable materials! 

9.

 

This  electrical  equipment  including  lines  and  plug  connections  should  not  be 
defective. 

10.

 

When refueling: 

-

 

stop the engine; 

-

 

do not smoke; 

-

 

do not spill. 

 

 

Take appropriate measures to protect your hearing. 

 

Beware of hot parts. 
 

 
 
 

Summary of Contents for VGEN002

Page 1: ...www heinner com VGEN002 Instructions GB Instruc iuni de utilizare RO...

Page 2: ...om the generator set 4 Refilling of the generating sets are not allowed during the operation 5 If the generator will be mounted in a closed room relevant safety regulations against fire and explosion...

Page 3: ...ing engine performance and life Use the 4 stroke oil SAE10W 40 is recommended for general all temperature use Other viscosities shown in the chart may be used when the average temperature in your area...

Page 4: ...er part of fuel filter Fix the fuel tank cap 3 STARTING THE ENGINE 1 Disconnect any load from the AC socket and turn off the alternating current circuit breaker 2 Turn the fuel valve to ON position 3...

Page 5: ...connection 2 Electrical equipment motor driven devices will produce lots of electric current when they start The following form will give you a reference when you connect them to generator Mode Amoun...

Page 6: ...tion networks the total length of lines for a cross section of 1 5 mm2 should not exceed 60 m for a cross section of 2 5 mm2 this should not exceed 100 m Notice When you want to connect the generator...

Page 7: ...h or operating hour interval whichever occurs first ITEM Daily First month or 20 Hrs Every 3 months or 50 Hrs Every 6 months or 100 Hrs Every year or 300 Hrs Engine oil Inspection Change Air cleaner e...

Page 8: ...ase dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station for reclamation Do not throw it in the tras...

Page 9: ...spark plug must be properly gapped and free of deposits 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug...

Page 10: ...y tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 4 Fuel filter service The filter prevents dirt or water which may be in fuel t...

Page 11: ...remove and empty the filter cup b Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container c Replace the filter cup and tighten securely d Loosen the carburetor drain s...

Page 12: ...he fuel reaching the carburetor NO Clean the fuel filter cup YES If the engine still does not start take the generator to an authorized dealer Replace the spark plug WARNING Be sure there is no spille...

Page 13: ...ASOLINE GENERATOR Model XXXX Displacement 210CC 4 stroke AC voltage 230 50Hz Rated Power Output 2 8kw Max Power Output 3 0kw Speed 4000 r min Fuel Tank Capacity 12 2L Continuous operating time 10 hour...

Page 14: ...mental protection requirements in your country Petrol oil and petrol oil mixtures are hazardous waste and have to be treated as such Oil and fuel must not be disposed of with household waste Improper...

Reviews: