background image

 

 

GASOLINE GENERATOR 

(6)  When  the  temperature  of  engine  increase,  pull  back 
the wind-block door rod. See the arrow in the diagram.  
 
 
 
 

4. OPERATING METHODS OF GENERATOR 
 

In order to keep your generator in good condition, please follow the rules: 
(1) Avoid improper operation, make sure to make your generator ground connection. 
 

 

(2)  Electrical  equipment,  motor-driven  devices  will  produce  lots  of  electric  current 
when  they  start.  The  following  form  will  give  you  a  reference  when  you  connect 
them to generator. 
 

Mode 

Amount of watt 

Setting 

Example 

Starting 

Rated 

Setting 

Starting 

Rated 

 

● Bulb

 

 

● Heating 

setting 
 

 
 

X1 

 
 

X1 

Bulb 

 

TV 

Bulb 

 
 

100 W 

 
 

100 VA 

(W) 

 

 
 

100 VA 

(W) 

 

 
 

● Fluorescent 

lamp 
 
 
 

 
 

X1 

 
 

X1.5 

 

 

fluorescent lamp 

 

 

40 W

 

fluorescent lamp 

 
 

40 VA 

(W) 

 

 
 

60 VA 

(W) 

 

 
 

● Motor drive

setting  

 
 

X3~5 

 
 

X2 

Refrigerator 

 

Fan 

Refrigerator 

 

1500 W 

 
 

4500~ 

7500 VA 

(W) 

 

 
 

3000 VA 

(W) 

 

 

 

 

 

Summary of Contents for VGEN002

Page 1: ...www heinner com VGEN002 Instructions GB Instruc iuni de utilizare RO...

Page 2: ...om the generator set 4 Refilling of the generating sets are not allowed during the operation 5 If the generator will be mounted in a closed room relevant safety regulations against fire and explosion...

Page 3: ...ing engine performance and life Use the 4 stroke oil SAE10W 40 is recommended for general all temperature use Other viscosities shown in the chart may be used when the average temperature in your area...

Page 4: ...er part of fuel filter Fix the fuel tank cap 3 STARTING THE ENGINE 1 Disconnect any load from the AC socket and turn off the alternating current circuit breaker 2 Turn the fuel valve to ON position 3...

Page 5: ...connection 2 Electrical equipment motor driven devices will produce lots of electric current when they start The following form will give you a reference when you connect them to generator Mode Amoun...

Page 6: ...tion networks the total length of lines for a cross section of 1 5 mm2 should not exceed 60 m for a cross section of 2 5 mm2 this should not exceed 100 m Notice When you want to connect the generator...

Page 7: ...h or operating hour interval whichever occurs first ITEM Daily First month or 20 Hrs Every 3 months or 50 Hrs Every 6 months or 100 Hrs Every year or 300 Hrs Engine oil Inspection Change Air cleaner e...

Page 8: ...ase dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station for reclamation Do not throw it in the tras...

Page 9: ...spark plug must be properly gapped and free of deposits 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug...

Page 10: ...y tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 4 Fuel filter service The filter prevents dirt or water which may be in fuel t...

Page 11: ...remove and empty the filter cup b Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container c Replace the filter cup and tighten securely d Loosen the carburetor drain s...

Page 12: ...he fuel reaching the carburetor NO Clean the fuel filter cup YES If the engine still does not start take the generator to an authorized dealer Replace the spark plug WARNING Be sure there is no spille...

Page 13: ...ASOLINE GENERATOR Model XXXX Displacement 210CC 4 stroke AC voltage 230 50Hz Rated Power Output 2 8kw Max Power Output 3 0kw Speed 4000 r min Fuel Tank Capacity 12 2L Continuous operating time 10 hour...

Page 14: ...mental protection requirements in your country Petrol oil and petrol oil mixtures are hazardous waste and have to be treated as such Oil and fuel must not be disposed of with household waste Improper...

Reviews: