11.
Maintenance
Use only genuine or equivalent specification replacement parts.
All parts are available through Heiniger dealers.
Use only qualified personnel for electrical repairs.
Always contact an authorized service centre if you are unsure how to rectify a problem or in
the event of malfunctions not contained in this manual.
Only perform maintenance when the grinder is disconnected from the power.
Electric motor
Periodically remove an outer Euro guard and disc and use dry compressed air to blow any
dust build up from inside the plastic electric motor cover and on the motor. Failure to keep
the motor dust free may reduce the cooling ability of the motor and cause it to cut out due to
overheating. See
3.2 Thermal overload
Do not disturb the collars fitted to the motor shaft, if they are moved they must be
refitted and trued to the shaft by qualified personnel. Failure to do so may cause
vibration. Keep the motor shaft, collars, disc nuts & washers clean and dry at all times, if
required clean with a little kerosene and dry thoroughly.
If the grinder is to be stored use anti rust on the shaft and collar, ensure this is cleaned off
before using.
Periodically check the condition of the power cord, replace if worn or damaged.
Foot
Ensure that feet are fitted and secure; failure to do so may lead to the grinder becoming
dangerously unstable.
Switch
Ensure the silicone boot covering the switch remains intact and in place. Failure to do so will
shorten the life of the switch. Replace damaged switches immediately.
Pendulum hook
If the pendulum hooks are damaged replace them before the grinder is used.
Cross arm
Periodically remove the Cross arm assembly and clean any dust or grease from inside the
tube nuts and collets and the thread on the telescopic tube.
Euro guard
The grinder is fitted with Euro guards that enclose the disc; these guards are integral to the
safe use of the grinder. At all times maintain the guards in correct working order, they must
fit the grinder correctly and securely. In the event of damage they must be repaired or
replaced before the grinder is used. When fitting the outer Euro guard to the grinder ensure
a new comb will fit between disc and guard without touching both disc and guard.
Discs
Keep the steel boss in the centre of the disc dry and free of dirt and grease.
If the discs are to be stored use anti rust on the boss. Ensure this is cleaned off before
using. Ensure that no anti rust gets on the face of the disc.
It is essential that the discs are not subject to abuse or neglect. Damage may occur
that will render the discs unusable.
Note:
The discs may be hazardous if used in a damaged condition.
If discs become damaged they must be replaced. Use only genuine Heiniger replacement
discs.
The discs are fitted to the grinder when dispatched and are protected by the Euro
guard. This is the best way to protect the discs when transporting.
When not fitted to the grinder the discs should be bolted to the clamp plate and
protected from knocks or being dropped.
Clamp plate
The clamp plate must be protected from damage as the discs are.
Pendulum
Refer to the pendulum manual for maintenance instructions.