7.
Initial start-up
Note:
Do not attempt to start the grinder unless this manual has been fully read and
understood.
Before starting the grinder ensure that the disc nuts are tight.
The on/off switch for the grinder is located on the front of the motor housing.
Ensure that the switch is in the off (up) position before connecting the grinder to a power
source.
Do not start the grinder unless the Euro guards are fitted and you are wearing safety
glasses.
Do not attempt to grind until the grinder is at full speed.
8.
Assembly
8.1
Assembly
The Euro grinder is dispatched fully assembled, however it must be set up before being
used for grinding, for full setup instructions refer to
9. Grinder operating instructions
Note:
The voltage specified on the grinder and that of the local power supply must match.
The grinder may only be connected to an AC power supply.
In the event that the grinder is operated from a generator, the power supply must not
exceed that specified on the grinder.
Note:
When removing the grinder from the case use two adults and lift the grinder
as illustrated.
Loosen the two Cross arm tube nuts
(9.)
and lift the Cross arm
(13.)
to its full height. Re-
tighten the tube nuts while holding the Cross arm at its full height.
8.2
Euro guards
The Euro grinder is fitted with guards enclosing the discs to protect the user during
use. See
2.2 Proper use
&
2.4 Further measures for avoiding accidents.
The Euro guards must remain in place at all times unless performing maintenance. It is
necessary to remove the outer part of the Euro guard to remove and refit the discs. The
outer part of the Euro guard is secured with three screws & nuts. When refitting the Euro
guards always use all three screws & nuts, tightened securely.
8.3
Fitting the discs onto the grinder
Note:
Unplug the grinder from power before proceeding. The outer Euro guard on
either
side must be removed to remove or fit a disc. The thread on the left-hand shaft is
left-handed. Always use the washer.
8.3.1
Slide the disc onto the shaft of the grinder, ensuring the collar on the shaft and the disc are
free from dirt, dust or any other foreign matter, tighten the disc nut.
8.3.2
Once both discs are fitted and tightened, check by placing a flat hand onto each disc and
try to move the discs in opposite directions. If either disc moves on the shaft the nuts are
not tight. Re-tighten and check again. Always refit the Euro guards.
Note:
The discs fitted to the grinder have been individually checked for balance. It must be
noted that it is possible for the glue and/or the emery to throw the balance off, see
11.
Troubleshooting