Service diagnosis
29
Domestic air conditioner
10.Service Diagnosis
10.1 Caution for Diagnosis
The operation lamp flashes when any of the following errors is detected.
●
1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions,
disabling equipment operation.
2. When a signal transmission error occurs between the indoor and outdoor units. In either case, conduct
the diagnostic procedure described in the following pages.
10.2 Problem Symptoms and Measures
e
r
u
s
a
e
M
f
o
s
li
a
t
e
D
m
e
tI
k
c
e
h
C
m
o
t
p
m
y
S
None of the units
operates
Check the power supply.
Check to make sure that the rated voltage is supplied.
Check the indoor PCB
Check to make sure that the indoor PCB is broken
Operation
sometimes stops. Check the power supply.
A power failure of 2 to 10 cycles can stop air conditioner
operation.
●
Equipment
operates but does
not cool, or does
not heat (only for
heat pump)
Check for faulty operation
of the electronic
expansion valve.
Set the units to cooling operation, and compare the
temperatures of the liquid side connection pipes of the
connection section among rooms to check the opening and
closing operation of the electronic expansion valves of the
individual units.
Diagnosis by service port
●
pressure and operating
current.
Check for insufficient gas.
Large operating
noise
and
vibrations
Check the installation
condition.
Check to make sure that the required spaces for
installation (specified in the Technical Guide, etc.) are
provided.
Summary of Contents for JZ050-C1
Page 11: ...Pinping diagrams 9 Domestic air conditioner 4 Pinping diagrams EEV EEV...
Page 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Page 15: ...Wiring diagrams 13 Domestic air conditioner Wiring diagrams...
Page 57: ...Circuit diagrams 55 Domestic air conditioner 13 2Module board circuit diagram...
Page 58: ...Sincere Forever...
Page 59: ...Wall Mounted Type DC Inverter FREE MATCH NEW1 5P Series SERIES JZ050 C1...