Functions and control
15
Domestic air conditioner
2
Wh_c<-8
Max_hz2 99HZ/99 HZ
3
Wh_c<-2
Max_hz3 99HZ/95 HZ
4
Wh_c<5
Max_hz4 88HZ/87 HZ
5
Wh_c<10
Max_hz5 70HZ/83 HZ
6
Wh_c<17
Max_hz6 59HZ/64 HZ
7
Wh_c<20
Max_hz7 49HZ/60 HZ
8
Wh_c>
=
20
Max_hz8 42HZ/56 HZ
Remarks: The above are the maximum frequency limitations of the complete appliance which are
affected by the environment, and they have nothing to do with the ability of the indoor unit.
Refrigeration/dehumidification mode:
Serial No.
Temperature scope
Frequency limitation
(
09K/12K
)
1
Wh_c<16
Max_hz1 31HZ/52 HZ
2
Wh_c<22
Max_hz2 37HZ/55 HZ
3
Wh_c<29
Max_hz3 47HZ/63 HZ
4
Wh_c<32
Max_hz4 54HZ/68 HZ
5
Wh_c<40
Max_hz5 62HZ/85 HZ
6
Wh_c<48
Max_hz6 64HZ/71 HZ
7
Wh_c>=48
Max_hz7 33HZ/47 HZ
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system. When the
starting ability is not the maximum, its maximum frequency limitation is calculated by the following
●
equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability
=
the actual running system ability*the maximum frequency which is limited by the temperature
and under the condition of maximum ability/the maximum designing ability of the system
Refrigeration/dehumidification mode:
Heating mode:
●
The calculation of the actual output frequency:
●
F= F-ED-*(rated frequency)
×
K
F
●
-ED-*(rated frequency)= The frequency which is limited by the outdoor environment temperature
Notes:
The indoor setting
airflow speed
Low
Medium
Quiet
The percentage of the
rated frequency K
(09K/12K)
70%/70%
85%/85% 54%/42%
The indoor setting
airflow speed
Low
Medium
Quiet
The percentage of the
rated frequency K
(09K/12K)
80%/80%
90%/90% 51%/50%
Summary of Contents for JZ050-C1
Page 11: ...Pinping diagrams 9 Domestic air conditioner 4 Pinping diagrams EEV EEV...
Page 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Page 15: ...Wiring diagrams 13 Domestic air conditioner Wiring diagrams...
Page 57: ...Circuit diagrams 55 Domestic air conditioner 13 2Module board circuit diagram...
Page 58: ...Sincere Forever...
Page 59: ...Wall Mounted Type DC Inverter FREE MATCH NEW1 5P Series SERIES JZ050 C1...