Wiring layout 

Each string requires two cables for connecting the solar generator to the power inverter. We recommend the use of special 
solar cable conforming to standard IEC 60228, Class 5 for this purpose. It should have a minimum cross-section of 4 mm². 
Cable  losses  should  be  <1%.  The  cross-section  of  the  cable  should  be  adjusted  accordingly  to  minimise  loss  over  larger 
distances.  

IMPORTANT: Ensure that pin- and sleeve-type connectors are correctly inserted into each other! 

The strings (+ and - leads) are laid to the power inverter and connected to the DC inputs. The module plugs are marked 
accordingly. The cable on the positive (+) plug of the module should be connected to the positive (+) input of the power 
inverter.  Proceed  in  a  similar  way  with  the  negative  (-)  connection.

 

The  two  strings  (+  and  -)  should  be  laid  together  to 

prevent the forming of conductor loops. The cable should run through the roof at a single point, if possible. 

The  solar  cables  must  be  fitted  to  the  power  inverter  using  only  suitably-certified,  compatible  plug-in  connectors.  These 
plug-in 

connectors 

are 

secured 

to 

the 

solar 

cable 

with 

special 

crimping 

pliers.  

It is vital to observe polarity of the strings when connecting them to the inverter. Please ensure not to interchange the + 
and  –  cables.  Use  a  multimeter/voltmeter  to  check  the  individual  strings  for  correct  polarity,  and  to  verify  their  voltage, 
before connecting them to the power inverter.  

Installation  and/or  connection  of  the  power  inverter(s)  should  be  carried  out  in  accordance  with  the  manufacturer’s 
instructions (Fig. 7). 

Max. Systemspannung 
Max. system voltage 
Tension système maxi 
1000 VDC 

   Typ 
   Type 
   Type 

   Anzahl 
   Numbers 
   Nombre 

Typ 

   Type 
   Type 

Anzahl 

   Numbers 
   Nombre 

Typ 

   Type 
   Type 

Anzahl 

   Numbers 
   Nombre 

NeMo® 54 P 195 

26 

NeMo® 54 P 225 

24 

NeMo® 60 P 240 

23 

NeMo® 54 P 200 

26 

NeMo® 54 P 230 

24 

NeMo® 60 P 245 

22 

NeMo® 54 P 205 

26 

NeMo® 54 P 235 

24 

NeMo® 60 P 250 

22 

NeMo® 54 P 210 

25 

 

 

NeMo® 60 P 255 

22 

NeMo® 54 P 215 

25 

 

 

NeMo® 60 P 260 

22 

NeMo® 54 P 220 

25 

  

  

NeMo® 60 P 265 

22 

 

Fig. 7: Number of modules for connection in series 

IMPORTANT:  Various  string-lengths  are  possible,  depending  on  module  output  and  the  type  of  power 
inverter used (see Fig. 7)! 

Parallel connection of PV modules 

Please  note  that  15A  fuse  protection  is  required  when  connecting  more  than  two  strings  of  our  modules  in  parallel.  The 
maximum reverse-current load is 15A. This may be exceeded in the event of a defect occurring, if more than two strings are 
connected in parallel.

 

 
Electrical installation 

Connection  of  the  power  inverter  to  the  public  grid  MUST  be  carried  out  by  a  properly-authorised  specialist  firm.  Pay 
attention to the requirements set out in DIN VDE 0298-3 regarding cable installation.  

 

CAUTION:  High  DC  voltages  are  present  even  with  small  amounts  of  light-input.  NEVER  touch  bare  +  or  - 
terminals while the system is in operation. 

Earth (ground) connection 

Requirements  regarding  lightning  conductors  and  excess-voltage  protection  depend  on  local  conditions.  The  firm  carrying 
out  the  installation  work  is  responsible  for  ensuring  that  the  module  frames  are  correctly  earthed  (grounded)  at  the 
positions indicated (see Fig. 8). An M4 screw is specified for earthing  (grounding) purposes. This must be secured with a 
split or toothed washer, in order to ensure that the Eloxal finish is properly penetrated.  

Summary of Contents for NeMo 54 P 195

Page 1: ...Installation and Operating Instructions www heckert solar com 03 12 2014 Manufactured with sustainable energy Installation and Operating Instructions...

Page 2: ...alent of the corresponding mains network operator along with the relevant health and safety and accident prevention measures Failure to observe these stipulations may result in grave personal injury o...

Page 3: ...nverter while under load can result in fatal injury due to arcing NEVER disconnect the solar generator from the power inverter while it is still connected to the network 2 General information regardin...

Page 4: ...ote and reported immediately in writing Our modules are normally delivered in an upright position on a non returnable pallet so that one person can remove the individual units without risk of back inj...

Page 5: ...itions You should therefore multiply the module s indicated Isc and Uos values by a factor of 1 25 when determining the voltage ratings of components current ratings of conductors and sizes of fuse fo...

Page 6: ...snow load and type of roof rafter or purlin type may require the fitting of a set of crossbars Please consult with Heckert Solar before considering any other type of installation The modules must not...

Page 7: ...any material that may result in the module being exposed to and therefore damaged by sharp or pointed edges or uneven structures The snow load at base sk measured in kN m is calculated using local lev...

Page 8: ...perly inserted Plug in connectors conform to protection class IP67 and sockets to IP65 Both components are therefore permanently protected from dust Please pay careful attention to the instructions su...

Page 9: ...ig 7 Max Systemspannung Max system voltage Tension syst me maxi 1000 VDC Typ Type Type Anzahl Numbers Nombre Typ Type Type Anzahl Numbers Nombre Typ Type Type Anzahl Numbers Nombre NeMo 54 P 195 26 Ne...

Page 10: ...int For integrated roof construction of the HS_P M xxx_4 Solrif R modules on e g slate shingle seam concrete tile etc an additional test for external fire spread according to the standards ENV 1187 4...

Page 11: ...GmbH Carl von Bach Strasse 11 D ll liability for infringement of patents or other third party rights that might arise from the operation of these modules is likewise excluded unless otherwise specific...

Page 12: ...12...

Page 13: ...ng the wire in place squeeze the crimp tool handles together until the ratchet releasses 4 Pressed Asembled Push contact with cable into the connector housing until you hear the contact give audible c...

Reviews: