9. SPECIFICATIONS
27
Installation & Owner‘s Manual
Model
Rated power/AMPS
Power supply
Auto/Manual startup, error alarm, timer,etc
R134a(1200g)
Operation control
Protection
E-heater power
Refrigerant
Outlet water temp.
Water side exchanger
Inlet pipe Dia.
Outlet pipe Dia.
Material
Motor power
Air circulation way
Net weight
Safety condenser,copper tube
wrapped around outside of storage tank
Hydrophilic aluminum fin, inner groove copper tube
80W
28W
Φ650×1920mm
Φ560×1680mm
3000W
R134a(900g)
3000W
Max. pressure
1.0MPa
Water tank cap.
Water-heating cap.
1450W
3000W
3800W/17A
4300W/18.7A
220-240V~ 50Hz
220-240V~ 50Hz
Drain pipe Dia.
DN20
DN20
DN20
PT valve Dia.
DN20
300L
190L
Water pipeline system
Exchanger
air side
Dimension
Default 55°C
(38-60°C adjustable)
R134a(1200g)
3000W
Default 55°C
(38-65°C adjustable)
Default 60°C
(38-70°C adjustable)
HWHM-TDF190/1.5-H31 HWHM-TDF300/3.5-H31
Table. 9-1
94kg
117kg
T30A 250VAC
80W
Φ650×1920mm
300L
145.5kg
T30A 250VAC
T20A 250VAC
Fusible link type
The test conditions:
Ambient temperature 15/12°C(DB/WB),
Water temperature from 15°C up to 45°C.
High-pressure Protector, Over-load Protector,
Temp Controller&Protector, Electric Leakage Protector, etc
3000W
4300W/18.7A
220-240V~ 50Hz
HWHM-TDF300/3.5E-H31
outlet/inlet vertically, duct connection available
ENGLISH