HeatStar F170470 Operating Instructions And Owner'S Manual Download Page 11

10

Convection Construction Heater

Operating Instructions and Owner’s Manual

WARNING:

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS 
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE 
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE 
AGENCY.

PARTS ORDERING INFORMATION:

PURCHASING: 

Accessories may be purchased at any HEATSTAR local dealer or 

direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 866-447-2194 • WWW.HEATSTARBYENERCO.COM
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in 
all communication.

LIMITED WARRANTY

 

The company warrants this product to be free from imperfections in material or 
workmanship, under normal and proper use in accordance with instructions of The Company, 
for a period of one year from the date of delivery to the buyer. The Company, at its option, 
will repair or replace products returned by the buyer to the factory, transportation prepaid 
within said one year period and found by the Company to have imperfections in material or 
workmanship. 

If a part is damaged or missing, call our Technical Support Department at 866-447-2194. 

Address any Warranty Claims to the Service Department, HEATSTAR, Inc., 4560 W. 160TH 
ST., CLEVELAND, OHIO 44135. Include your name, address and telephone number and 
include details concerning the claim. Also, supply us with the purchase date and the name 
and address of the dealer from whom you purchased our product. 

The foregoing is the full extent of the responsibility of the Company. There are no other 
warranties, express or implied. Specifically there is no warranty of fitness for a particular 
purpose and there is no warranty of merchantability. In no event shall the Company be liable 
for delay caused by imperfections, for consequential damages, or for any charges of the 
expense of any nature incurred without its written consent. The cost of repair or replacement 
shall be the exclusive remedy for any breach of warranty. There is no warranty against 
infringement of the like and no implied warranty arising from course of dealing or usage of 
trade. This warranty will not apply to any product which has been repaired or altered outside 
of the factory in any respect which in our judgment affects its condition or operation. 

Some states do not allow the exclusion or limitation of incidental or consequential damages, 
so the above limitation or exclusion may not apply to you. This Warranty gives you specific 
legal rights, and you may have other rights which vary from state to state.

HEATSTAR, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194 
HEATSTAR is a registered trademark of HEATSTAR, Inc.
© 

2019

, HEATSTAR. All rights reserved

HEATSTAR, Inc., reserves the right to make changes at any time, without notice or obligation, 
in colors, specifications, accessories, materials and models.

HS80CVX
HS200CVX

OPERATING INSTRUCTIONS 
AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

Model #

PRODUCT REGISTRATION:  Thank you for your purchase.  
Please log in to http://www.egiregistration.com to register your product.

70486 - 

2019

 - CB

NEVER LEA

NEVER LEA

NEVER LEA

VE THE HEA

VE THE HEA

VE THE HEA

TER UNA

TER UNA

TER UNA

TTENDED WHILE BURNING!

TTENDED WHILE BURNING!

TTENDED WHILE BURNING!

Summary of Contents for F170470

Page 1: ...liance Extinguish any open flame Shut off gas to appliance Service must be performed by a qualified service agency This is an unvented gas fired portable heater It uses air oxygen from the area in whi...

Page 2: ...UTION FAILURE TO FOLLOW THESE VENTILATION REQUIREMENTS MAY RESULT IN SOOTING DAMAGE SPECIFICATIONS GENERAL INFORMATION RETAIN THIS MANUAL FOR FUTURE REFERENCE FOR QUESTIONS PROBLEMS MISSING PARTS BEFO...

Page 3: ...or operate heater unless the shells are fully extended and locked into position 4 Use only propane gas 5 Use only VAPOR WITHDRAWAL propane supply If there is any question about vapor withdrawal ask yo...

Page 4: ...d area before you return Properly trained service people must repair any leaks check for further leakages and then relight the appliance for you ODOR FADING NO ODOR DETECTED Some people cannot smell w...

Page 5: ...S AS SHOWN THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INTO PLACE CAUTION NEVER IGNITE AND OR RUN THIS HEATER UNLESS THE SHELLS ARE FULLY EXTENDED AND...

Page 6: ...in the heater The flame is essentially yellow with some blue at the base of the fame adjacent to the burner There is no strong disagreeable odor eye burning or other physical discomfort There is no sm...

Page 7: ...the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desired left side of chart 3 Read the cylinder size required All heaters should have full cylinde...

Page 8: ...er Electrode 1 11 28619 Igniter Electrode Bracket 1 12 28620 Pilot Burner Head 1 13 28621 Pilot Burner Orifice 1 14 28622 Pilot Gas Supply line 1 15 28623 Igniter Lead 1 16 20735 Piezo Igniter With Nu...

Page 9: ...85 Burner Cone 1 7 28584 Burner Orifice Holder 1 8 28583 Burner Orifice 1 10 28595 Burner Supply Tube 1 11 28594 Fuel Inlet Supply tube 1 12 28591 Variable Rate Valve Knob 1 13 28587 Valve Control Ass...

Page 10: ...hours Provide ventilation air exchange either natural or mechanical as required to maintain acceptable indoor air quality USA 8 Hr Time weighted average OSHA 29 CFR 1926 55 App A Canada 8 hr time weig...

Page 11: ...ress or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no event shall the Company be liable for delay caused by imperfecti...

Page 12: ...alimentation en gaz l appareil L entretien doit tre effectu par un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif aliment au gaz n est pas ventil Il utilise l oxyg ne...

Page 13: ...POUR TOUS VEUILLEZ LIRE LES INSTRUCTIONS AVANT D UTILISER CET APPAREIL DE CHAUFFAGE TABLE DES MATI RES SP CIFICATIONS 2 AVERTISSEMENTS 2 PR CAUTIONS LI ES AU FONCTIONNEMENT 3 PR CAUTIONS LI ES LA S CU...

Page 14: ...te et verrouill e en position Consultez la feuille d assemblage pour obtenir les instructions 4 Utilisez uniquement du gaz propane 5 Utilisez uniquement une alimentation au propane LIMINATION DES MANA...

Page 15: ...ifier si du gaz s chappe Assurez vous qu ils aient a r l immeuble avant d y retourner Le personnel d entretien exp riment doit colmater toute fuite v rifier la pr sence d autres fuites puis se charger...

Page 16: ...MOINS QUE LES COQUES EXT RIEURES SOIENT COMPL TEMENT OUVERTES ET VERROUILL ES EN POSITION TAPE 1 APPAREIL TEL QUE RE U LA SORTIE DE L EMBALLAGE AVANT DE SOULEVER LA COQUE EXT RIEURE PROT GEZ VOUS LES...

Page 17: ...u ait br l 3 Tourner la valve de br leur principale la position basse claire V RIFICATION Un appareil de chauffage qui a t modifi ou qui ne fonctionne pas correctement risque d tre une cause de danger...

Page 18: ...us basse pr vue au bas du tableau 2 Allez ensuite directement au haut du tableau au temps d utilisation d sir c t gauche du tableau 3 Notez la dimension de la bonbonne requise Tous les appareils de tr...

Page 19: ...pport 1 12 28620 Veilleuse Head 1 13 28621 Veilleuse Orifice 1 14 28622 Pilote de ligne d alimentation en gaz 1 15 28623 Lead allumeur 1 16 20735 Allumeur pi zo lectrique avec crou 1 18 28624 Tube Bur...

Page 20: ...1 8 28583 Orifice du br leur 1 10 28595 Tube Burner Supply 1 11 28594 Le tube d admission de carburant Supply 1 12 28591 taux variable Valve Knob 1 13 28587 Assembl e Valve Control 1 14 28582 crou de...

Page 21: ...ur maintenir une qualit de l air int rieur acceptable Moyenne pond r e dans le temps sur 8 heures tats Unis OSHA 29 CFR 1926 55 App A Moyenne pond r e dans le temps sur 8 heures Canada Directives SST...

Page 22: ...ANK ESTA P GINA INTENCIONALMENTE SE DEJA EN BLANCO CETTE PAGE A T INTENTIONNELLEMENT LAISS E VIERGE NE JAMAIS LAISSER LE CHAUFF NE JAMAIS LAISSER LE CHAUFF NE JAMAIS LAISSER LE CHAUFFAGE SANS SUR AGE...

Page 23: ...ANK ESTA P GINA INTENCIONALMENTE SE DEJA EN BLANCO CETTE PAGE A T INTENTIONNELLEMENT LAISS E VIERGE NE JAMAIS LAISSER LE CHAUFF NE JAMAIS LAISSER LE CHAUFF NE JAMAIS LAISSER LE CHAUFFAGE SANS SUR AGE...

Page 24: ...n aucun cas l entreprise ne sera tenue responsable des retards caus s par des d fectuosit s ni des dommages indirects ni des d penses encourues sans son consentement crit quelle que soit leur nature L...

Page 25: ...odas las llamas expuestas Corte el suministro de gas al artefacto El mantenimiento debe ser realizado por una agencia de reparaci n calificada Este calentador port til a gas no tiene una fuente propia...

Page 26: ...PRECAUCIONES DE SEGURIDAD 3 ADVERTENCIA DE DISIPACI N DEL OLOR 4 CUIDADO INSTRUCCIONES SOBRE LA EXTENSI N DE LA CARCASA 5 INSTRUCCIONES DE USO 6 REPARACI N 6 TAMA O Y CAPACIDAD DE LOS CILINDROS DE PR...

Page 27: ...nsulte la hoja del conjunto adjunta para obtener las instrucciones 4 Utilice nicamente gas propano 5 Utilice nicamente suministro de propano con RECUPERACI N DE VAPOR Si tiene alguna pregunta sobre la...

Page 28: ...que ventilen el edificio y el rea antes de su regreso Un agente de servicios calificado debe reparar cualquier fuga revisar si hay otras fugas y volver a encender el artefacto por usted DISIPACI N DE...

Page 29: ...DEBE USAR EL CALENTADOR A MENOS QUE LA CARCASA EXTERNA SE ENCUENTRE BIEN EXTENDIDA Y COMPLETAMENTE TRABADA EN SU LUGAR CUIDADO NUNCA ENCIENDA O USE ESTE CALENTADOR A MENOS QUE LAS CARCASAS EST N EXTE...

Page 30: ...n original haya sido modificada o si no est funcionando correctamente Cuando el calentador funciona correctamente La llama arde en el interior del calentador La llama es fundamentalmente azul y puede...

Page 31: ...ire m nima esperada parte inferior del gr fico 2 Ascienda en la vertical hasta encontrar el tiempo de funcionamiento deseado a la izquierda del gr fico 3 Lea el tama o de cilindro requerido Todos los...

Page 32: ...odo Soporte 1 12 28620 Piloto Quemador Head 1 13 28621 Piloto del orificio del quemador 1 14 28622 Piloto de l nea de suministro de gas 1 15 28623 Conductor del encendedor 1 16 20735 Piezo encendedor...

Page 33: ...orificio 1 8 28583 Orificio del quemador 1 10 28595 Tubo del quemador de alimentaci n 1 11 28594 Tubo de entrada de suministro de combustible 1 12 28591 V lvula de Tasa Variable Perilla 1 13 28587 As...

Page 34: ...TENTIONALLY LEFT BLANK ESTA P GINA INTENCIONALMENTE SE DEJA EN BLANCO CETTE PAGE A T INTENTIONNELLEMENT LAISS E VIERGE NUNCA DEJE EL CALENT NUNCA DEJE EL CALENT NUNCA DEJE EL CALENTADOR DESA ADOR DESA...

Page 35: ...table del aire interior EE UU Promedio ponderado de 8 horas OSHA 29 CFR 1926 55 App A Canad Promedio ponderado de 8 horas Recomendaciones WorkSafe BC OHS Par te 5 1 y Reglamentaciones para lugares de...

Page 36: ...ue el comprador devuelva a la f brica con transportaci n prepagada dentro del mencionado per odo de un a o y que la Compa a determine que presentan imperfecciones materiales o de fabricaci n Si alguna...

Reviews: