Heatrae Sadia Multipoint 30H Fitting Instructions Manual Download Page 7

7

5.3 Choice of location 

 

`

National Wiring rules may contain restrictions 

concerning the installation of these products in 

bathrooms.

 

`

The product should be Horizontally wall 

mounted using the wall bracket supplied. The 

water connections must always be to the right 

of the product.

 

`

For servicing leave the following minimum 

distances; 250mm on right hand side and 

330mm on the left hand side. Refer to figure 1 

and the dimension table to determine a suitable 

position for the product.

WARNING

Ensure that the wall can support the full 

weight of the product (see Technical 

specifications)  and  that  there  are  no 

hidden services (electricity, gas, or water) 

below the surface of the wall.

5.  Before installation

5.1 Installation regulations

WARNING

Installation of the  product must be carried 

out by a qualified engineer in accordance 

with prevailing and national regulations as 

listed below.

 

`

Building Regulations

 

`

The Building Standards (Scotland)

 

`

The Building Regulations 

(Northern Ireland)

 

`

I.E.E Electrical Regs

 

`

UK Water Regulations

5.2 Installation requirements

Water supply

In an unvented system the pressure and flowrate is 

directly related to the incoming water supply. For this 

reason it is recommended that the maximum water 

demand is assessed and the water supply checked 

to ensure this demand can be satisfactorily met.

 

`

We suggest the minimum supply requirements 

should be 0.08MPa (0.8 bar) pressure.

 

`

A 15mm cold water supply is recommended.

 

`

The higher the available pressure and flow rate 

the better the system performance.

 

`

The water supply must be of wholesome water 

quality (Fluid Category 1 as defined by the Water 

Supply Regulations 1999).

Outlet/terminal fittings (taps,etc.)

 

`

The product can be used with most types of 

terminal fittings.

 

`

It is not recommended for supplying a shower.

 

`

All fittings, pipework and connections must have 

a rated pressure of at least 8 bar at 80°C. 

Summary of Contents for Multipoint 30H

Page 1: ...Multipoint Horizontal 30 and 50 litre Fitting Instructions...

Page 2: ...ise warranty details to customers Contents 1 Introduction 3 1 1 General 3 1 2 Symbols used 3 1 3 Abbreviations 3 1 4 Liabilities 3 2 Safety 4 2 1 General safety warnings 4 2 2 Recommendations 4 2 3 Sp...

Page 3: ...in product quality All the specifications stated in this document are therefore subject to change without notice Our liability as the manufacturer may not be invoked in the following cases Failure to...

Page 4: ...pass the thermal cut out in any circumstance 2 Safety 2 1 General safety warnings DANGER This product is unvented and as such becomes pressurised when in operation The combination of pressurisation an...

Page 5: ...posed of at end of life See Section 3 to 11 Electrical rating 3kW 240V 2 75kW 230V Capacities 30 or 50 litres Weight full 30 litre 42 5kg 50 litre 69 3kg Rated pressure 0 6MPa 6 bar Minimum recommende...

Page 6: ...per inner vessel which ensures an excellent standard of corrosion resistance The outer casing is a combination of resilient thermoplastic moldings and painted steel The product is supplied complete wi...

Page 7: ...iling and national regulations as listed below Building Regulations The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Water Regulations 5 2 Installatio...

Page 8: ...f valve 3 52 Where a manifold is used it should be sized to accept and discharge the total discharge from the discharge pipes connected to it 3 53 Where valves other than the temperature and pressure...

Page 9: ...ithstanding high temperature discharges of water and 3m from any plastic guttering system that would collect such discharges Tundish 3 54 The tundish should be vertical located in the same space as th...

Page 10: ...esistance of 4 No 28mm elbows at 1 0m each 4 0m Therefore the maximum permitted length equates to 14m As the actual length is 7m a 28mm D2 copper pipe will be satisfactory Safety device e g temperatur...

Page 11: ...he electrical supply The indicator light will illuminate during heating When the set temperature is reached the indicator light will go out The set temperature can be adjusted by rotating the knob loc...

Page 12: ...his pipe must be left open to atmosphere 8 Operation 8 1 General WARNING Do not block or restrict the discharge from any safety valve fitted Do not tamper with any safety valve fitted If water dischar...

Page 13: ...ure water flows freely from the valve s and through the discharge pipes Ensure the valve s reseat correctly when released The Expansion Vessel should have a precharge pressure of 0 35 MPa 3 5 bar This...

Page 14: ...relief valve intermittently A Expansion in mains not possible A Fit pack U2 see important installation points B Mains pressure exceeds 0 41 MPa 4 1 bar B Fit packs U1 and U2 C Pack U1 fitted without p...

Page 15: ...duct can therefore be disposed of through commercial non WEEE waste facilities Heatrae Sadia does not accept any liability under the WEEE directive This product is manufactured from many recyclable ma...

Page 16: ...hin 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product The product is not covered against damage by frost and the imme...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...m our website To support our corporate responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these fil...

Reviews: