Heatrae Sadia Multipoint 30H Fitting Instructions Manual Download Page 20

PN 36 00 5726  Issue 3

©

 Heatrae Sadia 2015

Please follow us online:

Electric Water Heating Co.

2 Horsecroft Place

Pinnacles

Harlow

Essex CM19 5BT

Tel: 0845 055 3811

E-Mail: [email protected]

SPD

Special Product Division

Units 9 & 10

Hexagon Business Centre

Springfield Road

Hayes

Middlesex UB4 0TY

Tel: 020 8606 3567

Parts Center

Tel: 0344 292 7057

www.partscenter.co.uk

Newey & Eyre

Unit 3-5 Wassage Way

Hampton Lovett Ind. Estate

Droitwich, Worcestershire  

WR9 0NX

Tel:  01905 791500

Fax: 01905 791501

UK Spares Ltd

Unit 1155

Aztec West

Almondsbury

Bristol BS32 4TF

Tel: 01454 620500

Alternatively contact your  

local supplying merchant  

or wholesale branch or use  

our online stockist finder at 

www.interpartspares.co.uk

PRODUCT RANGE

Full specification details on all our products are available to download from our website.

To support our corporate responsibility and sustainability charters and reduce our 

printed material we encourage you to download product brochures from our website.

In designing these files we have taken into account the need to access data on screen.

If you would like to receive a printed copy of our full product catalogue please call  

our literature hotline on 01603 420127.

Heatrae Sadia may introduce modifications to their products from time  

to time. Consequently, the details given in this brochure are subject to alteration 

without notice.

OUR NATIONWIDE NETWORK OF CUSTOMER SUPPORT ENGINEERS

Heatrae Sadia has its very own dedicated nationwide network of highly trained 

customer support engineers so you can have peace of mind that we’re always  

here to help.

 MADE IN

THE UK

5

5 YEAR

INNER

CONTAINER

WARRANTY

SPECIFICATION ADVICE HOTLINE

 

t |  01603 420220   e | [email protected]

AFTER SALES SERVICE

 

t |  0344 871 1535  e | [email protected] 
 

w | heatraesadia.com

20

Summary of Contents for Multipoint 30H

Page 1: ...Multipoint Horizontal 30 and 50 litre Fitting Instructions...

Page 2: ...ise warranty details to customers Contents 1 Introduction 3 1 1 General 3 1 2 Symbols used 3 1 3 Abbreviations 3 1 4 Liabilities 3 2 Safety 4 2 1 General safety warnings 4 2 2 Recommendations 4 2 3 Sp...

Page 3: ...in product quality All the specifications stated in this document are therefore subject to change without notice Our liability as the manufacturer may not be invoked in the following cases Failure to...

Page 4: ...pass the thermal cut out in any circumstance 2 Safety 2 1 General safety warnings DANGER This product is unvented and as such becomes pressurised when in operation The combination of pressurisation an...

Page 5: ...posed of at end of life See Section 3 to 11 Electrical rating 3kW 240V 2 75kW 230V Capacities 30 or 50 litres Weight full 30 litre 42 5kg 50 litre 69 3kg Rated pressure 0 6MPa 6 bar Minimum recommende...

Page 6: ...per inner vessel which ensures an excellent standard of corrosion resistance The outer casing is a combination of resilient thermoplastic moldings and painted steel The product is supplied complete wi...

Page 7: ...iling and national regulations as listed below Building Regulations The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Water Regulations 5 2 Installatio...

Page 8: ...f valve 3 52 Where a manifold is used it should be sized to accept and discharge the total discharge from the discharge pipes connected to it 3 53 Where valves other than the temperature and pressure...

Page 9: ...ithstanding high temperature discharges of water and 3m from any plastic guttering system that would collect such discharges Tundish 3 54 The tundish should be vertical located in the same space as th...

Page 10: ...esistance of 4 No 28mm elbows at 1 0m each 4 0m Therefore the maximum permitted length equates to 14m As the actual length is 7m a 28mm D2 copper pipe will be satisfactory Safety device e g temperatur...

Page 11: ...he electrical supply The indicator light will illuminate during heating When the set temperature is reached the indicator light will go out The set temperature can be adjusted by rotating the knob loc...

Page 12: ...his pipe must be left open to atmosphere 8 Operation 8 1 General WARNING Do not block or restrict the discharge from any safety valve fitted Do not tamper with any safety valve fitted If water dischar...

Page 13: ...ure water flows freely from the valve s and through the discharge pipes Ensure the valve s reseat correctly when released The Expansion Vessel should have a precharge pressure of 0 35 MPa 3 5 bar This...

Page 14: ...relief valve intermittently A Expansion in mains not possible A Fit pack U2 see important installation points B Mains pressure exceeds 0 41 MPa 4 1 bar B Fit packs U1 and U2 C Pack U1 fitted without p...

Page 15: ...duct can therefore be disposed of through commercial non WEEE waste facilities Heatrae Sadia does not accept any liability under the WEEE directive This product is manufactured from many recyclable ma...

Page 16: ...hin 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product The product is not covered against damage by frost and the imme...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...m our website To support our corporate responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these fil...

Reviews: