Heatrae Sadia Megalife CLV190 Installation Manual Download Page 2

Megalife Product Guide

2

Section 

 

 

 

 

           Page

1 Introduction ............................................... 2

General Requirements ............................. 4

 

Installation - General ................................ 5

Installation - Solar ..................................... 7

 

Installation - Auxillary Coil ........................ 8

 

6 Commissioning ......................................... 11

 

User Instructions ....................................... 12

 

8 Maintenance ............................................. 13

Fault Finding & Servicing ......................... 14

10 

Dimensions & Specifications ................... 16

11 Guarantee .................................................. 19

12 Contacts .................................................... 20

 

    

Contents

Thank you for purchasing a Heatrae Sadia Megalife cistern fed solar vented water heater. The Megalife solar is manufactured 
in the UK from top quality materials and meets all the latest relevant safety and constructional standards. The high grade 
Duplex stainless steel cylinder offers exceptional strength and corrosion resistance and is backed by a 25 year cylinder 
guarantee. Its performance and insulation levels meet the latest requirements of Building Regulation Part L.

The Megalife solar vented water heater must be fed from a cold water feed cistern located above the water heater and 
hot outlets to be served. The unit must have a suitable vent pipe installed on the outlet that is arranged to discharge 
over the cold water feed cistern. 

The Megalife solar water heaters are supplied with a dedicated solar coil in the lower part of the cylinder which must be 
connected to an indirect solar primary circuit. Various controls will be necessary to integrate the Megalife solar cylinder 
into a solar primary circuit which are not supplied with the Megalife. Ensure that manufacturer’s instructions for any 
ancillary solar primary circuit components are followed to ensure the correct integration of the Megalife solar into the 
solar primary circuit.

In addition to the solar primary coil heat exchanger units also have an additional heat exchanger coil located in the 
upper section of the cylinder for connection to an auxillary heat source such as a gas, oil or electric boiler. The units are 
supplied fitted with a thermostat and over-temperature thermal cut-out for the control of the auxillary primary heat input 
to the Megalife solar from the boiler selected. All models are supplied with one electric immersion heater for use as a 
back up heat source should the auxillary primary heat source be switched off.

1: Introduction

36005941_issue_07.indd   2

07/09/2017   08:40:30

Summary of Contents for Megalife CLV190

Page 1: ...Megalife Solar Vented Cistern Fed Water Heater Installation manual SOLAR DIRECT 36005941_issue_07 indd 1 07 09 2017 08 40 29...

Page 2: ...tlet that is arranged to discharge over the cold water feed cistern The Megalife solar water heaters are supplied with a dedicated solar coil in the lower part of the cylinder which must be connected...

Page 3: ...hot water from the safety devices to an appropriate place open to atmosphere where it will cause no danger to persons in or about the building Vented hot water storage systems 3 12 Vented hot water s...

Page 4: ...ously Water Byelaw 30 A vent pipe MUST be connected to the outlet of the heater This must rise continuously and be arranged to discharge into the feed cistern The vent pipe must have a minimum bore di...

Page 5: ...lly the pipework from the heater to the outlet fittings should be in 22mm pipe with short runs of 15mm pipe to the terminal fittings Pipe sizes may vary due to system design 3 5 Vent Pipe A vent pipe...

Page 6: ...UTLET VENT HOT COLD HOT COLD HOT INLET WATER SUPPLY CISTERN TANK COLD MAINS SUPPLY MAX HEAD 40m VENT PIPE Stop Valve OVERFLOW PIPE Fig 03 Typical Vented Solar Installation Schematic 36005941_issue_07...

Page 7: ...ure controller will control the operation of the solar pumped primary circuit to transfer heat from the solar collector panels to the cylinder via the lower solar primary coil heat exchanger refer to...

Page 8: ...y doubt contact a competent electrician 5 3 Wiring All electrical wiring should be carried out by a competent electrician and be in accordance with the latest I E E Wiring Regulations The Megalife sol...

Page 9: ...ns 1 5mm2 3 Core HOFR sheathed cable Indirect control wiring SPINDLE POSITIONS MINIMUM TEMP 10 C MAXIMUM TEMP 72 C APPROX 60 C ROTATE SPINDLE CLOCKWISE FOR TEMPERATURE INCREASE AND COUNTER CLOCKWISE F...

Page 10: ...Supply 1 2 3 G 1 Br Bl 2 0 GY 3 G 1 Br Bl 2 0 1 3 2 2 L N Programmer Boiler Pump Zone valve HTG Cylinder terminal block Room stat Zone valve DHW Junction box 3 2 3 L 1 N 2 3 HTG ON DHW ON L N 2 3 1 L...

Page 11: ...controls housing and its cable securely clamped Heating by the solar primary circuit is controlled by the solar differential temperature controller refer to the manufacturers installation instructions...

Page 12: ...upply The temperature adjustment is made by inserting a flat bladed screwdriver in the slot in the spindle on top of the thermostat and rotating see Fig 05 page 9 If in any doubt consult a competent e...

Page 13: ...laries by carefully pulling outwards from the immersion heater Note which order they are fitted Remove the terminal shroud Unscrew immersion heater backnut s and remove immersion heater from the unit...

Page 14: ...model installed and ensure the correct part is ordered 9 Fault Finding and Servicing 2 9 6 4 5 8 3 1 Fig 08 Spares 10 Item Description Part Number 1 Immersion heater lower 95 606 984 2 Immersion heate...

Page 15: ...low gradu ally decreases 1 Outlet flow rate exceeds inlet flow to cold water feed cistern 2 Flow starvation caused by opening further outlets 1 Install higher flow float valve Consider larger cold wat...

Page 16: ...min at 80 C 2 C Temperature rise is from 15 C to 60 C Indirect units tested to BS EN 12897 2006 Type Model Reference Dimensions mm Solar Auxiliary Coil Solar Surface Area sq m Solar Coil Rating kW Rat...

Page 17: ...per day kWh 24h per year kWh 365d 190 1 52 555 210 1 70 621 250 1 98 723 300 2 31 843 Indirect Model s CLV190 CLV210 CLV250 CLV300 Energy efficiency class C C C C Storage volume V in litres 190 210 2...

Page 18: ...ckness 50mm Immersion heater Alloy sheathed element and thermostat pocket in Duplex stainless steel plate Pipe connections All connections accept 22mm outside diameter pipe compression nuts and olives...

Page 19: ...e Republic of Ireland For installations outside these territories please contact either the Heatrae Sadia Heating Export Department Tel 44 1603 420191 or Baxi International Tel 44 1926 478323 for furt...

Page 20: ...acles Harlow Essex CM19 5BT T 0845 055 3811 E sales ewh co uk SPD Units 9 10 Hexagon Business Centre Springfield Road Hayes Middlesex UB4 0TY T 020 8606 3567 Parts Center T 0845 270 9800 W www partsce...