Megalife Product Guide
Table 04: Unit weights
Table 05: Standing heat loss
Type
Model
Reference
Nominal
Capacity
(litres)
Weight of
unit full
(Kg)
Weight
of unit
(Kg)
Solar
Indirect
190 SV Ind
190
243
43
210 SV Ind
210
264
50
250 SV Ind
250
308
51
300 SV Ind
300
367
58
Nominal
Capacity
(Litres)
Standing Heat Loss
per day
(kWh/24h)
per year
(kWh/365d)
190
1.52
555
210
1.70
621
250
1.98
723
300
2.31
843
Indirect
Model(s)
CLV190
CLV210
CLV250
CLV300
Energy efficiency class
C
C
C
C
Storage volume V in litres
190
210
250
300
Standing loss in W
80.0
81.7
82.5
96.3
Table: Technical parameters in accordance with European Commission regulations 814/2013 and 812/2013
Table: Figures measured in accordance with KIWA Test Criteria
for compliance with UK Building and Water Regulations
36005941_issue_07.indd 17