Unvented Hot Water Cylinder
PRODUCT SPECIFICA
TION (1)
General Requirements
Important: Please read and understand this product guide before installing the MEGAFLO
Eco
Solar water heater. Incorrect installation may
invalidate the guarantee. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of knowledge and experience, unless they have been given supervision or instruction concerning the use of the appliance by a person
responsible for their safety. The MEGAFLO
Eco
Solar must be Installed (Section 2), Commissioned (Section 2) and Maintained (Section 3) by a
competent installer in accordance with Building Regulation G3 (England and Wales), Technical Standard P3 (Scotland) or Building Regulation P5
(Northern Ireland) and the Water Fitting Regulations (England and Wales) or Water Byelaws (Scotland). Following Installation and Commissioning,
the operation of the heater should be explained to the user (Section 4) and this product guide left with them for future reference.
Siting the MEGAFLO Eco (See Figure 1 below)
The MEGAFLO
Eco
Solar unit must be vertically floor mounted. It can be placed anywhere convenient provided the discharge pipe(s) from its safety
valves can be correctly installed. Areas that are subject to freezing must be avoided. Ensure that the floor is of sufficient strength to support the
“full” weight of the unit (refer to Tables 3 and 4 on page 9 for unit weights). Pipe runs should be kept as short as possible for maximum economy.
Access to associated controls, immersion heaters and indirect controls should be possible for servicing and maintenance of the system.
Please do not install valves or pipework (except discharge pipe) within 50mm (2”) of the T&P relief valve to allow your insulation set to be fitted.
The insulation set is important to ensure heat and energy conservation. See page 16 for more information.
To aid installation, the MEGAFLO
Eco
Solar is provided with lifting points located in the base moulding and a lifting handle. The lifting handle
should be fully threaded onto the outlet boss before use. Once the MEGAFLO
Eco
Solar is suitably positioned the lifting handle should be removed
to allow connection of the outlet pipework. The weights of the units are noted in the Tables 3 and 4, (p 9).
Figure 1 - Schematic Installation Details
TO HOT OUTLETS
T&P VALVE
8 BAR PRESSURE RELIEF VALVE
TUNDISH
DISCHARGE PIPE
DRAIN COCK
AUXILIARY PRIMARY
RETURN
AUXILIARY PRIMARY
FLOW
SECONDARY RETURN
TAPPING (IF REQUIRED)
MAINS WATER
SUPPLY
BALANCED COLD WATER
CONNECTION (IF REQUIRED)
ELEMENT/CONTROLS
HOUSING
3 BAR PRESSURE
REDUCING VALVE
STOP COCK (IF USED
IN THIS POSITION)
SOLAR PRIMARY
RETURN
SOLAR PRIMARY
FLOW
EXPANSION
VESSEL
SOLAR CONTROLS
HOUSING
Summary of Contents for Megaflo Eco Solar Series
Page 1: ...Unvented Direct Indirect Solar Megaflo Product Guide Hot Water Cylinders...
Page 10: ...10 Unvented Hot Water Cylinder NOTES PRODUCT SPECIFICATION 1...
Page 26: ...26 Unvented Hot Water Cylinder NOTES INSTALLATION AND COMMISSIONING INSTRUCTIONS 2...
Page 34: ...34 Unvented Hot Water Cylinder MAINTENANCE AND SERVICING 3...
Page 35: ...Unvented Hot Water Cylinder 35 MAINTENANCE AND SERVICING 3...
Page 37: ...Unvented Hot Water Cylinder 37 User Instructions Guarantee Customer Service USER GUIDE 4...