#46543 User Guide
HeatLink Digital Thermostat
L646543
November 6, 2007
Page 2
#46543 User Guide
Mounting Hole
Wiring Terminals
Back Terminal Plate
Wiring Hole
➂
➂
➂
➂
➂
➂
➂
➂
➂
➃
➃
➄
Screw Cover
(removed)
Center Screw
Front Control Panel
➀
➁
➅
➅
Installation
➀
Remove the Screw Cover.
➁
Remove the Center Screw to separate the Front Control Panel and
Back Terminal Plate.
➂
Mount the Back Terminal Plate using the supplied screws.
➃
Pull the Wiring through the Wiring Holes.
➄
Loosen the Wiring Terminals screws, connect the wires to each of the
terminals as per the wiring diagram, and tighten the screws.
➅
Finish the install by placing the Front Control Panel on to the Back
Terminal Plate, fasten the Center Screw, and replace the Screw Cover.
Mounting Location
• Mount the thermostat at 5' (1.5 m) from the fl oor
• Mount on inner walls only, and at least 2' (0.6 m) away from any outer
wall. Avoid entrances.
• Mount away from any direct heat sources like: air vents, radiators, and
lights.
• Avoid Moisture, it is damaging to electronics, so avoid installing
in areas that would contain high humidity or condensation (e.g.
bathrooms or greenhouses).
• Do not cover or enclose, allow for proper air circulation, to get a good
measurement of the current air temperature.
Auto-setback mode
(Requires a timer setback signal)
In auto-setback mode, the 46543 operates automatically between
comfort mode (
blinking) and setback mode (
blinking)
according to the schedule of a timer thermostat (46643 or 46673).
Freeze Protection mode
In Freeze Protection mode: instead of simply turning the system
off, this thermostat prevents freezing by maintaining a
6°C (43°F)
minimal temperature. This mode is ideal for unoccupied buildings.
Setback mode
In setback mode, the temperature is set lower to conserve energy, the
default is
17°C (63°F)
. This mode is ideal for areas that are unoccupied.
To change the setback temperature (while in setback mode):
PRESS
OR
to change the setpoint to a lower
(-) or higher (+) temperature
PRESS
The Current Setpoint Temperature will blink
indicating that it can be changed
PRESS
to confi rm the desired setpoint
The Measured Temperature will
return after 5 seconds
Comfort mode
In comfort setpoint mode, the temperature is set to a comfortable level,
the default is
21°C (70°F)
. This mode is ideal for occupied areas. To
change the comfort setpoint temperature (while in comfort mode):
PRESS
OR
to change the setpoint to a lower
(-) or higher (+) temperature
PRESS
The Current Setpoint Temperature will blink
indicating that it can be changed
PRESS
to confi rm the desired setpoint
The Measured Temperature will
return after 5 seconds
FREEZE PROTECTION
COMFORT MODE
AUTO-SETBACK MODE
SETBACK MODE
PRESS
OR
To cycle through the modes
User Operation
In all modes, if a fl oor sensor is installed, blinking indicates that the fl oor temperature is outside the limits set by the
FL
and
FH
parameters.
FH
FH