Confi guration

This thermostat comes pre-confi gured for a radiant fl oor heating system with a separate 
boiler control and should normally not need further adjustment. The parameters can be 
adjusted for fi ne tuning the system or adapting to other applications.

To access the Parameter Menu PRESS 

& HOLD

For 5 seconds

After 30 seconds of non use the thermostat will automatically exit the Parameter Menu.

OR

PRESS

to cycle though parameters

&

PRESS

to reset a parameter to its 
factory default

J1

: adjusts the type of 

system

(default: 

"Hot"

)

the thermostat can be used 

for heating OR cooling

Cy

: PI regulation time cycle 

Cy

Cy

in minutes

(default: 

6

 minutes)

Range: 1-99, A0-A9 {100-

109}, B0-B9 {110-119}, C0 

{120}

The constant time cycle the 

thermostat uses to translate 

the % output from the PI 

calculation to an on/off time 

of the heat demand.

On

: Minimum call for heat 

in minutes

(default: 0 minutes)

Range: 0 - half the PI time 

cycle (Cy)

OF

: Minimum interval 

OF

OF

between on cycles in 

minutes 

(default: 0 minutes)

Range: 0 - half the PI time 

cycle (Cy)

bp

: PI regulation band 

amplitude value in degrees

(default: 

1.5°C/2.7°F

)

Range: 0.01-12.7

The on (100%) / off 

(0%) point during the PI 

operation

PRESS OK Button

to switch between

"Hot" 

(Heating) and

"

CLd"

 (Cooling)

 (Cooling)

PRESS OK Button

screen starts to blink 

indicating adjustment

PRESS OK Button

screen starts to blink 

indicating adjustment

PRESS OK Button

screen starts to blink 

indicating adjustment

PRESS OK Button

screen starts to blink 

indicating adjustment

  

  

PRESS "

-

" or "

+

To change value

PRESS "

-

" or "

+

To change value

PRESS "

-

" or "

+

To change value

PRESS "

-

" or "

+

To change value

PRESS OK to validate 

PRESS OK to validate 

PRESS OK to validate 

PRESS OK to validate 

Grey shaded parameters should only be adjusted by a heating professional.

End

: exits the Parameter 

Menu

J0

: adjusts the temperature 

scale (default: 

"°C"

)

PRESS OK Button

to exit the parameter menu

PRESS OK Button

to switch between

°C

 and 

°F