Heatilator • RAVE4013I • 2184-900 Rev. E • 8/09
25
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Figure 7.5
1. Top Vent - Horizontal Termination - (continued)
Top Vent - Horizontal Termination
Venting with 2 elbows
Note
: Use SLP Series
components only.
V Minimum
H
1
+ H
2
MAXIMUM
RAVE4013I
90° Elbow
1 ft.
305 mm
1 ft.
305 mm
2 ft.
610 mm
2 ft.
610 mm
4 ft.
1.2 m
3 ft.
914 mm
6 ft.
1.8 m
4 ft.
1.2 m
15 ft.
4.6 m
H + H
1
MAX. =15 ft. (4.6 m)
V + H + H
1
MAX. = 40 ft. (12.2 m)
Note
: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.