01-02
21
28881 Rev G
NOVUS REAR DIRECT VENT
5. APPLIANCE PREPARATION
a. Log Set
The log set should look similar to that in
Figure 35.
WARNING! RISK OF CARBON MONOXIDE!
Do not hit or strike glass. Do not operate this appli-
ance with the glass removed, broken, or not sealed.
c. Placing the Rock Wool
Place a small amount of 1/2 diameter pieces
(dime-size) of rock wool on the burner pan so
that the rock wool touches but does not cover the
holes in the burner pan. This will provide the
glowing embers look. See Figure 37.
Figure 36
Placing the Vermiculite and Lava Rock
(top logs removed for clarity)
Figure 37
Placing the Rock Wool
(top logs removed for clarity)
Figure 34 - Control Access Panel Removal
Figure 35 - Log Set
b. Placing the Lava Rock and Vermiculite
See Figure 36for lava rock and vermiculite
placement.
6. GLASS AND SCREEN REPLACEMENT
See page 27 of this instruction manual.
7. CONTROL ACCESS PANEL PLACEMENT
Place the control access panel as shown in Figure 38.
Figure 38 - Replace Control Access Panel