01-02
19
28881 Rev G
NOVUS REAR DIRECT VENT
b. Electronic Ignition
1)
This electronic ignition appliance requires a 110V AC supply to operate. It is suggested that a switched
110V junction box with two switched outlets be installed to power the optional remote control and/or fan.
2)
Only heater-listed appliances may be connected to a thermostat. If connecting a 24V thermostat (not
supplied), disconnect the black wire from the transformer at the ignition control. Connect the thermostat
wires between the ignition control and the black wire (from transformer). See Figure 29.
Figure 29 - Electronic Ignition Wiring Diagram
Figure 29a
NO additional wire is
supplied by Hearth
Technologies Inc.
c. Junction Box Wiring
We recommend you operate the two outlets on
separate circuits. This allows independent
operation of the appliance and fan. Independent
operation is obtained by using minimum 14-3
with ground Romex and separating the two outlets
by breaking out the tab as shown in Figure 30.
Figure 30 - Junction Box Detail