45
Heatilator • NEVO3630I-B, NEVO4236I-B Installation Manual • 2378-980 Rev. E • 4/16
10
10
Finishing
A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or
fi
nishing materials must not interfere with
air
fl
ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or
fi
nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
NOTICE:
Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190
°
F.
Note:
If using the optional
fi
nishing trim for the Modern Front
facing,
fi
nish wall material must not be installed within 3 in.
(76 mm) of the
fi
replace opening. See Figure 14.5.
• Seal joints between the
fi
nished wall and appliance top
and sides using a 300 ºF minimum sealant. Refer to
Figure 10.1.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci
fi
ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
42.25 in. (NEVO3630)
48.25 in. (NEVO4236)
1/8 in. reveal
all sides
30.22 in.
6 in.
6 in.
Figure 10.1 Marble/Granite Cut Dimensions
• Figure 10.1 shows the dimensions for cutting marble/
granite if the optional Finishing Trim is not used.
• The dimensions given assume a 1/8 in. reveal around
the
fi
replace opening.
Figure 10.2 Non-combustible Facing Diagram
0 in.
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
0 in.
Finish wall material may be
combustible - Top and Sides
3 in. (76 mm)
3 in.
(76 mm)
3 in.
(76 mm)
Gray shading represents
clearance needed for optional
Finishing Trim that may be used
with the Modern Front. No facing
material may be used within the
shaded area.
Figure 10.3 Clearance for Optional FInishing Trim (Modern Front)
Note:
Fireplace MUST be elevated 1
1/2 in. (38 mm) off
fl