41
Heatilator • NEVO3630I-B, NEVO4236I-B Installation Manual • 2378-980 Rev. E • 4/16
B. Wiring Requirements
Intelli
fi
re
TM
Plus Ignition System Wiring
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™
Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
RC100 (optional)
RC200 (optional)
Valve
Power supply
plugged into
junction box
Module
Pilot
assembly
Wiring
harness
Battery
holder
RED
BLK
RED
RED
BRN
BLK
BLK
ORG
GRN
ORG
WHT
Wall
switch
wires
BLK
RED
WHT
RC300 (optional)
Figure 8.2 IntelliFire™ Plus Intermittent Pilot Ignition (IPI) Wiring Diagram