A. Gas Log/Lighter Provisions
A certi
¿
ed gas log lighter or decorative gas log set can be
installed in this
¿
replace.
• Maximum input is 100,000 BTU/hr.
•
Decorative gas appliance must be certi
¿
ed to
ANSI Z21.60
“Standard for Decorative Gas Appliances for Installation
in Vented Fireplaces”.
• Must be installed in accordance with the
National Fuel
Gas Code, ANSI Z223.1.
• A log set must incorporate a gas shutoff.
• Log set requires the damper to be locked fully open.
Knockouts are provided on both sides of the
¿
replace and in
refractories for 1/2 in. (13 mm) iron pipe.
• We recommend you seal refractory around pipe with
¿
replace mortar or high temperature, noncombustible
sealant.
• Repack insulation from the knockout around the pipe.
• Maintain 1-1/2 in. (38 mm) air space around the pipe for
4 in. (102 mm) beyond the
¿
replace.
• See Figure 7.1.
Firebox
Repack
Insulation
Knockout
Combustible
Materials
Maintain air clearance
to combustibles.
Gas Line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
Gas Line
1-1/2 in.
(38 mm)
air space
Refractory
Seal with
fireplace mortar
or high temp
noncombustible
sealant
4 in.
(102 mm)
Outer Shell
of Fireplace
Figure 7.1
Gas Line Installation
7
7
Accessories
Asphyxiation Risk
•
Damper must be locked open when gas logs
installed.
Gas
¿
re generates fumes.
WARNING
Fire Risk
• For use with solid wood fuel or decorative
gas appliance only.
• DO NOT install unvented gas logs.
WARNING
Fire Risk
Explosion Risk
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components
Report damaged parts to dealer.
WARNING
¨
¨