Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
61
Inspect
Maintenance Tasks
Doors, surrounds and fronts
1.
Access condition of screen and replace as necessary.
Recommend addition of screen if
one is not present.
2.
Inspect for scratches, dents or other damage and repair as necessary.
3.
Verify no obstructions to air
fl
ow through the louvers.
4.
Verify proper clearance to combustible household objects is maintained.
Gasket seal, glass assembly and glass
1.
Inspect gasket seal and its condition.
2.
Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.
3.
Con
fi
rm there is no damage to glass or glass frame. Replace as necessary.
4.
Verify that latches engage properly, clip studs are not stripped, and glass attachment
components are intact and operating properly. Replace as necessary.
5.
Clean glass using a nonabrasive cleaner such as Brasso®. Replace glass assembly if
severely coated with silicate deposits that cannot be removed.
Valve compartment and
fi
rebox top
1.
Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these
areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.
2.
Remove any foreign objects.
3.
Verify unobstructed air circulation.
Logs
1.
Inspect for broken, damaged, or missing logs. Replace as necessary.
2.
Verify correct log placement and no
fl
ame impingement causing sooting. Correct as
necessary.
Firebox
1.
Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.
2.
Replace appliance if
fi
rebox has been perforated.
Burner ignition and operation
1.
Verify burner is properly secured and aligned with pilot or ignitor.
2.
Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if
necessary.
3.
Replace rockwool with new dime-sized and shaped pieces. Do not block ports or obstruct
lighting paths.
4.
Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.
5.
Inspect for lifting or other
fl
ame problems.
6.
Verify air shutter is clear of dust and debris.
7.
Inspect ori
fi
ce for soot, dirt or corrosion.
8.
Verify manifold and inlet pressures. Adjust regulator as required.
9.
Inspect pilot
fl
ame strength. Clean or replace ori
fi
ce as necessary.
10.
Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean
with emery cloth or replace as required.
11.
Verify millivolt output. Replace as necessary.
Venting
1.
Inspect venting for blockage or obstruction such as birds’ nests, leaves, etc.
2.
Con
fi
rm that termination cap remains clear and unobstructed by plants, etc.
3.
Verify that termination cap clearance to subsequent construction (building additions, decks,
fences or sheds) has been maintained.
4.
Inspect for corrosion or separation.
5.
Verify weather stripping sealing and
fl
ashing remain intact.
6.
Inspect draft shield to verify it is not bent, damaged or missing.
Remote controls
1.
Verify operation of remote.
2.
Replace batteries in remote transmitters and battery-powered receivers.
3.
Verify batteries have been removed from battery back-up in IPI systems to prevent premature
battery failure or leaking.
Maintenance and Service Tasks: