28
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
7
7
Appliance Preparation
Figure 7.1 Cover Plate, Top of Appliance
A. Convert from Top Vent to Rear Vent
• Remove the screw holding heat shield cover plate to top
of appliance and set aside. See Figure 7.1
• Remove three remaining screws holding the plate
surrounding
fl
ue. See Figure 7.3. Remove plate and set
aside.
Figure 7.3 Cover Plate, Remove Screws
• Remove four screws holding inner plate surrounding the
fl
ue. See Figure 7.4. Remove inner plate and discard.
Figure 7.4 Inner Plate, Top of Appliance
Sharp Edges
• Wear protective gloves
and safety glasses during
installation.
CAUTION
Note:
If the appliance is to be top vented discard this plate
and replace the screw you removed. If the appliance is to
be rear vented, continue to the next step and Figure 7.2.
• Remove the white insulation and set aside. See
Figure 7.2.
Figure 7.2 Remove White Insulation