14
Hearth & Home Technologies • CNXT70PLUS • 4034-105 Rev C • 09/05
C. System Wiring
Note:
The CNXT70PLUS must be electrically wired and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code, CSA C22.1.
Figure 8.1
Intermittent Pilot Ignition Wiring Diagram
CNXT70PLUS Requirements
• This gas appliance requires a 110VAC supply to the gas appliance junction box for operation. A wiring diagram is shown
in Figure 8.1.
• The CNXT70PLUS is equipped with an intermittent pilot control valve which operates on a 3 volt system. See ignition
wiring diagram, Figure 8.1.
• The CNXT70PLUS is supplied with a 3 volt AC transformer, which requires the installation of the supplied junction box.
It is highly recommended that the junction box be installed at this time to avoid future reconstruction.
Note:
Wire terminal latch can become
damaged if excessive force is used
when releasing wire. Please use caution
in pressing retainer.