CALIBER DESIGNER DIRECT VENT
4. Install the Light Kit (optional)
If not installing the light kit, proceed to Step 5.
a.
Remove the log/grate assembly by unscrewing the
four screws located on the left and right sides of
the assembly. See Figure 43.
Figure 43 - Remove Log/Grate Assembly
Figure 44 - Remove Burner Assembly
Figure 45 - Remove Sheet Metal Cover Plate
Figure 46 - Cover Plates
Figure 47 - Light Base Assembly
b.
Remove the burner assembly by unscrewing the
four screws holding it in place. See Figure 44.
c.
Remove the sheet metal cover plate by
unscrewing the two screws located in the corners.
See Figure 45.
d.
If you have a V series appliance, skip to Step
4.g. Open the control access panel to view the
valve compartment. Locate the two cover plates.
See Figure 46. Using a short phillips screwdriver,
remove the two screws on the cover plate. Repeat
for other side.
e.
Take the light base assembly and position it into
the rectangular hole. Using the screws removed
in 4.d., attach the light base to the valve plate.
See Figure 47. Repeat for the other side.
f.
Remove one green wire and screw from the power
box and attach that wire and screw to the firebox
support hole located in the bottom right-hand
corner of the firebox support.
Place the flange on the power box into the formed
tab in the bottom pan. Peel the plastic off the Velcro
and press it onto the bottom pan. Plug the light
base assembly connector into the power box. See
Figure 48. With the wall switch in the OFF
position, plug the power box cord into the junction
box on the switched outlet side. For intermittent
pilot ignition appliances, plug the transformer into
the outlet of the power box. With the wall switch in
the OFF position, plug the power box cord into
the junction box on the switched outlet side.
Æ