22
35593 Rev G
01/04
CALIBER DESIGNER DIRECT VENT
b. Intermittent Pilot Ignition
1)
This appliance requires a 110VAC supply to the appliance junction box for operation. A wiring diagram is
shown in Figure 39.
2)
This appliance is equipped with an intermittent pilot control valve which operates on a 3V system.
3)
This appliance is supplied with a battery pack and a 3V transformer, which requires the installation of the
supplied junction box. We highly recommend that the junction box be installed at this time to avoid
reconstruction. The battery pack requires two D cell batteries (not included). Batteries cannot be placed in
the battery pack while using the 3V transformer. Conversely, the transformer must be unplugged if the
battery pack is used.
Figure 39 - Intermittent Pilot Ignition Wiring Diagram
c. Junction Box Wiring
We recommend you operate the two outlets on
separate circuits. This allows independent
operation of the appliance and fan. Independent
operation is obtained by using minimum 14-3 with
ground Romex and separating the two outlets by
breaking out the tab as shown in Figure 40.
6. Junction Box Installation Instructions
a
. Remove the junction box assembly from the valve
compartment.
b.
If the box is being wired from the OUTSIDE of the
appliance:
1)
Loosen two screws on the Romex connector,
feed the necessary length of wire through the
connector and tighten the screws.
2)
Make all necessary wire connections to the
receptacle and assemble the receptacle and
cover to the junction box.
3)
Attach the junction box assembly to the
outside of the appliance with the two screws
provided.
c.
If the box is being wired from the INSIDE of the
appliance:
1)
Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
Figure 40 - Junction Box Detail
2)
Loosen the two screws on the Romex
connector, feed the necessary length of wire
through the connector and tighten the screws.
3)
Make all necessary wire connections to the
receptacle and assemble the receptacle and
cover to the junction box.
4)
Attach the junction box assembly to the inside
of the appliance with the two screws provided.
d.
If the box is not to be wired at the time of appliance
installation, assemble the receptacle and cover to
the box and install on the inside of the appliance.