Heatilator • AVEO Series DV • 4058-210 Rev P • 1/13
18
5
5
Framing and Clearances
A. Select Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Fig-
ure 5.1).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
of traffi c and away from furniture and draperies.
NOTICE:
Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1
Appliance Locations
In addition to these framing dimensions, also reference the
following sections:
• Clearances and Mantel Projections (Sections 3.C. and 3.D.)
• Vent Clearances and Framing (Section 6)
Rear vent
One 45° elbow
Horiz Term
Rear Vent
Two 90° elbows
Horiz Term
Rear Vent
One 90° elbow
Vert Term
Top Vent
One 90° elbow
Horiz Term
No elbows
Horiz Term
A
A
A
A
A
A
C
B
B
E
F
D
1/2 in. (13 mm) min.
appliance to
combustibles
D
F
1 in. (25 mm)
min. pipe to
combustibles
E
1/2 in. (13 mm)
min. appliance
to combustibles
Alcove
Installation
C
1 in. (25 mm)
min. pipe to
combustibles
G
Drywall
48 in.
(1219 mm)
maximum
A
B
C
D
E
F
G
inches
34
31 1/4
12
34
36 5/8
44 3/4
35
mm
864
794
305
864
930
1137
889
Model
ADVT3428
ADVR3428