Heath Zenith Replacement Motion Sensor SH-5407 Owner'S Manual Download Page 3

-3-

598-1155-01

Motion

 Least Sensitive 

Most Sensitive

Sensor

Motion

The sensor is less sensitive to motion directly to-
wards it, most sensitive to motion across its fi eld 
of view.

 

Maximum Range 

Maximum  

 

  Coverage 

Angle

8 ft. 

(2.4m)

70 ft. 

(21m)

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

 

Avoid aiming the control at:

•  Objects that change temperature rapidly, such 

as 

heating vents and air conditioners.

 These 

heat sources could cause false triggering.

•  Areas  where 

pets or traffi c

 may trigger the 

control.

•  

Nearby large, light-colored objects

 refl ecting 

light may trigger the shut-off feature. Do not point 
other lights at the sensor.

MAX

MIN

RANGE

ON-TIME

10  5   1  TE

S

T

MINUTE

S

MIN MAX

180°

  Loosen the clamp screw 

in the sensor ball joint and 
gently rotate the sensor.

  Walk through the cover-

age area noting where 
you are when the lights 
turn on (also, the LED will 
fl ash several times when 
motion is detected). Move 
the sensor head up, down, 
or sideways to change 
the coverage area. 

Keep 

the sensor at least 1" 
(2.5 cm) away from the 
lamps.

 Adjust the RANGE as 

needed. RANGE set too 
high may increase false 
triggering.

 

Secure the sensor head by tightening the 
clamp screw.

 Do not overtighten the screw.

  Set the amount of TIME you want the lights to stay 

on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fi re. Do not aim the lamps 
at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range  . . . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . . .  Up to 180°
Electrical Load . . . . . . . .  Up to 500 Watt (4.2A) Maximum 

Incandescent [Up to 250 Watt 
maximum each lamp holder.]

Power Requirements . . .  120 VAC, 60 Hz
Operating Modes . . . . . .  TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . . .  1 , 5, 10 minutes
Range  . . . . . . . . . . . . . .  Adjustable 

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifi cations at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

  Turn the RANGE control to the mid position and 

the ON-TIME control to the TEST position.

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Summary of Contents for Replacement Motion Sensor SH-5407

Page 1: ...UTO MANUAL MODE ON TIME ON TIME Ifyougetconfusedwhileswitchingmodes turnthe power off for one minute then back on After the calibration time 11 2 min the control will be in the AUTO mode 10 5 1 TEST 1...

Page 2: ...ept at least 2 51 mm from the sensor Black to Black White to White Red Sensor Wire to Black Lamp Wire Optional Connect additional load across the white and red wires Total lighting load including lamp...

Page 3: ...or sideways to change the coverage area Keep the sensor at least 1 2 5 cm away from the lamps Adjust the RANGE as needed RANGE set too high may increase false triggering Secure the sensor head by tigh...

Page 4: ...ay also write to HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Purch...

Page 5: ...dalidades del interruptor Para PRUEBA Cuando lo prenda por primera vez espere unos 1 1 2 minutos hasta que el circuito se calibre PRUEBA AUTOM MODO MANUAL ON TIME 10 5 1 TEST ON TIME 10 5 1 TEST Para...

Page 6: ...o Controles Controles Controles Tornillo Sujetador Siga las indicaciones que vinieron con sus aparatodeluzparamontajeyajustedelaparato de luz Mantenga las l mparas normales PAR 38 por lo menos a 25 mm...

Page 7: ...ga al detector por lo menos a 1 pulgada 2 5 cm de las l mparas Fije la sensibilidad RANGE comonecesite Demasiada sensibilidad puede aumentar las falsas alarmas Asegure la punter a de la cabeza del det...

Page 8: ...lame al 1 800 858 8501 s lo para hablar en ingl s de 7 30 AM a 4 30 PM CST L V Usted puede tambi n escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio T cn...