Long Range Scanning
RMLD-FR can detect
methane up to 100’ away.
Actual distance may vary due to
target surface and environmental
conditions.
As scanning distance increases,
the returning laser light level
decreases. As the maximum
distance is approached, a
“low return signal” tone is heard.
You will need to move in closer.
Scanning Distance of 50’+
- Slow down the scanning rate.
- Take care in pointing the laser.
- Use the spotter laser or IMAGE
mode to ensure proper scanning
of the target area.
- Be aware of the ground elevation.
Scanning across the top of a knoll
or past the edge of a structure
can result in
beam skip
(a sudden
change in distance) which may
give you a false detection.
- Obstructions or variations in the
landscape can cause a
dark zone
(an area where the laser doesn’t
scan). Look for the best angle
to thoroughly scan these areas.
Scanning up a hillside may cause
beam skip or dark zones around
the foundation of a structure.
Dealing With False Detections
Several conditions may occur
that will cause the algorithm
to give a detection indication.
The most common are:
• Abrupt or jerky motions cause
the scanning distance to rapidly
change.
• Overly strong returns due to
strong reflectors.
False detection most commonly occurs in the 50 feet (15 m) range, due to the
beam footprint becoming very large. Abrupt motion, and change in terrain or
distance to an object may cause the DMD to give a short low detection.
To verify if the detection is due to a leak, pause at this distance, aim off
to the side, and re-sweep across the area to determine if gas is present.
Scanning from a long range to short range will also minimize false detection.
Strong reflections off certain surfaces (e.g., black garbage bags, water
droplets, glass, polished surfaces, stones, license plates, reflectors, etc.)
may give a false detection. Re-scan the area from a slightly different angle.
The laser light is selective to methane, and will not false-alarm on other hydrocarbons.
- Beam Skip is a sudden change in distance.
- Dark Zone is an area where the laser doesn’t scan.
They are caused by obstructions such as rocks, trees,
structures, and uneven landscape.
Dark Zone
(an area where the
laser doesn’t scan)
Beam Skip
(a sudden change
in distance)