SAF-T WRAP INSULATION:
Saf-T Wrap is available in tee sections and 24” lengths,
therefore two lengths will be required for each 4’ section of
Sat-T Liner. Saf-T Wrap must cover the Saf-T liner from the
appliance tee or the top of the smoke chamber area to within
8” but not closer than 4” of the top of the masonry chimney.
See Fig. 19 for a topview.
FIG.19
FIG.18
COVER PLATE:
Saf-T Liner black Cover Plate provides a decorative finish to the
installation of a side wall masonry chimney. See Fig. 18.
OPENING OF THE CHIMNEY
NOTE: Wear eye protection and dust respirator.
An opening for the liner system will have to be made for any existing masonry chimney without an opening. If there is an
opening, it may need to be expanded in order to insert the tee take off into the removable tee or accommodate the support
system chosen.
To make the initial opening into the masonry chimney, select a brick that is at the level you want the stove pipe to enter the wall
(at least 18” from unprotected combustibles unless a listed wall penetration assembly or other approved method is used). The
wall penetration assembly must be above the appliance. Drill a series of holes in the mortar around the perimeter of the brick
1/4” 8lbs density
refractory ceramic
fiber
Aluminum
Jacket
STORM COLLAR:
A Storm Collar is required at the top of the masonry chimney to
support the liner in conjunction with the Top Plate. Install the
Storm Collar directly below the expanded portion of the Saf-T
Liner section by tightening the clamp screw. The Storm Collar
will then rest on the Top Plate. See Figs. 17 and 24.
FIG.17