SAF-T LINER COMPONENTS:

A variety of components are available to suit most installations such as Lengths, Adjustable Lengths, Elbows, Tees, Increasers,
Reducers, Top Plates,  Support Clamp, Cover Plate,  Rain Cap and Saf-T Wrap.
- Plan the installation of your appliance and Saf-T Liner in such a way that your connector run is as short and straight as
possible.

- Having an installation with too long and / or with multiple bends, can reduce system draft which can affect the operation, and
/ or performance of your appliance and / or chimney system.  Choose the proper diameter of connector pipe.  It must be al least
equivalent to the stove outlet diameter.

- All joints between sections of Saf-T Liner  must be secured with four (4) stainless steel pop rivets per joint (supplied).

- Saf-T Liner must be installed with the  pilot holes in the up position, smallest diameter end in the direction of the appliance,
arranged so condensate will drain within the connector pipe and into the appliance or into the Tee.

- Saf-T Liner used as a connector pipe  must be sloped upward towards the chimney at least 1/4 inch per foot of horizontal run.

FIXED LENGTHS:

Saf-T Liner is available in 12”, 18”, 24”, 36” and 48” fixed Lengths.   To
determine the length and number of liner sections required complete the
following:  Calculate the number of fixed and/or telescoping lengths
required to line the chimney and extend not more than 6” above the
termination of the masonry chimney (Remember each fixed length’s
measurement must be reduced by 2” to account for overlap of each
section).  See Fig. 8.

FIG.8

TELESCOPING LENGTHS:

The telescoping section 

will adjust 

from 50” to

90”  for required height.    NOTE: Two is the
maximum number of telescoping lengths which
may be installed above the appliance tee.  A
telescoping section between the appliance and
clean out tee will allow for both radial and vertical
adjustments during the installation.  See Fig. 9.

FIG.9

SLIP CONNECTOR:

The Slip Connector provides flexibility in completing a run 

and may be used

to allow expansion and contraction of the system.

  While the female end

will fasten securely to a section, the male end can be easily adjusted to
match the required length into another section.   The Slip Connector provides
from 2" to 14" of usable length (includes joint).

 See Fig. 10

FIG.10

Pilot Holes

(4)

Pilot Holes

(4)

Inside

Section

Outside

Section

Pilot Holes

(4)

Inside

Section

Outside
Section

50” - 90”

48”

Summary of Contents for Saf-T Liner

Page 1: ...on instructions Saf T Liner has been tested and listed using all the supports sections etc described herein Deletion or modification of any of the required parts or materials may seriously impair the...

Page 2: ...he roof of a building and not less than 2 feet above any portion of the building within ten feet see Fig 1 Materials 024 304 Stainless Steel 024 316L Stainless Steel Includes 1 8 Stainless Steel Blind...

Page 3: ...2 and Figure 2 Saf T Wrap is available for tee sections and in 24 lengths Saf T Wrap must cover the Saf T Liner from the appliance tee or the top of the smoke chamber area to within 8 but not closer...

Page 4: ...A B Always wear eye protection and heavy gloves throughout installation Wear eye protection and dust respirator whenever in contact with creosote soot mortar or insulation Before the installation of t...

Page 5: ...assembly will be supported from the top of the chimney The installer must verify that there is at least 1 inch clearance to combustibles outside a 3 nominal layer of masonry as well as 1 inch clearan...

Page 6: ...horizontal run FIXED LENGTHS Saf T Liner is available in 12 18 24 36 and 48 fixed Lengths To determine the length and number of liner sections required complete the following Calculate the number of...

Page 7: ...ze can have a negative impact of chimney performance and safety Use these components only when appropriate See Fig 13 RAIN CAP Saf T Liner Rain Cap is made of stainless steel and required to cap the l...

Page 8: ...it may need to be expanded in order to insert the tee take off into the removable tee or accommodate the support system chosen To make the initial opening into the masonry chimney select a brick that...

Page 9: ...ON CAUTION must be used when working on a roof Proper and safe scaffolding should be used for a safe installation of the Saf T Liner Always use a respirator and eye protection when using Saf T Wrap MA...

Page 10: ...p Plate supporting the upper sections of the liner system Slide the Rain Cap into the female portion of the Saf T Liner section and secure with the four self drilling screws provided See Figs 5 and 25...

Page 11: ...is not used the single wall connector pipe must be at least 18 from combustible construction material Clearances from the solid fuel burning appliances to combustible materials must be strictly adhere...

Page 12: ...y walls and cause cracking buckling distortion and or burnout in chimney liners A chimney liner damaged in such a way as to permit leakage of flue gases should be repaired or replaced Since there is a...

Page 13: ...workmanship For products installed after January 1 2009 for a period of Ten 10 years from original installation we will provide replacement product with a similar or like quality of available Selkirk...

Reviews: