HeatFab Saf-T Liner Installation And Maintenance Instructions Manual Download Page 7

7

ELBOWS:

Saf-T Liner fixed Elbows are available in 15°, 30°, 45° and 90°.  An Adjustable 90° Elbow
is also available.  

Elbows allow a change in direction in the system, can be used when an

offset is needed or to connect to an insert.   See Fig. 11.

TEES:
A variely of Tees are available to suit most installations such as: Appliance
Tee, Cleanout Tee, Fixed Tee, Crimped Tee and Tee Caps and Tee Plugs.
See Fig. 12

INCREASERS AND REDUCERS:
Saf-T Liner Increasers and Reducers are designed to increase or
reduce the size of a Saf-T Liner system to accommodate a range
of flue sizes, appliances and installations.  NOTE: Increasing or
decreasing a chimney size can 

have 

a negative impact of chimney

performance and safety.  Use these components only when
appropriate.  See Fig. 13

RAIN CAP:

Saf-T Liner Rain Cap is made of stainless steel and required to cap the liner system
against precipitation and creates a venturi effect to enhan

ce draft.  Secure i

n positon

with stainless steel screws providing easy removal for inspection and cleaning.  See
Fig. 14.

FIG.11

FIG.12

FIG.13

FIG.14

TOP CLAMP:

Saf-T Liner can also be supported from the top of the masonry chimney by using a
Top Clamp.  See Fig. 15.

FIG.15

TOP PLATE:

Saf-T Liner Top Plates are available in different dimensions such
as 13” x 13”, 13” x 18” and 18” x 18”.    A Top Plate is used to
seal off the liner system at the top of the masonry chimney and
to support the liner in conjunction with the Storm collar.  See
Fig. 16.

FIG.16

Topview

and

Frontview

Summary of Contents for Saf-T Liner

Page 1: ...on instructions Saf T Liner has been tested and listed using all the supports sections etc described herein Deletion or modification of any of the required parts or materials may seriously impair the...

Page 2: ...he roof of a building and not less than 2 feet above any portion of the building within ten feet see Fig 1 Materials 024 304 Stainless Steel 024 316L Stainless Steel Includes 1 8 Stainless Steel Blind...

Page 3: ...2 and Figure 2 Saf T Wrap is available for tee sections and in 24 lengths Saf T Wrap must cover the Saf T Liner from the appliance tee or the top of the smoke chamber area to within 8 but not closer...

Page 4: ...A B Always wear eye protection and heavy gloves throughout installation Wear eye protection and dust respirator whenever in contact with creosote soot mortar or insulation Before the installation of t...

Page 5: ...assembly will be supported from the top of the chimney The installer must verify that there is at least 1 inch clearance to combustibles outside a 3 nominal layer of masonry as well as 1 inch clearan...

Page 6: ...horizontal run FIXED LENGTHS Saf T Liner is available in 12 18 24 36 and 48 fixed Lengths To determine the length and number of liner sections required complete the following Calculate the number of...

Page 7: ...ze can have a negative impact of chimney performance and safety Use these components only when appropriate See Fig 13 RAIN CAP Saf T Liner Rain Cap is made of stainless steel and required to cap the l...

Page 8: ...it may need to be expanded in order to insert the tee take off into the removable tee or accommodate the support system chosen To make the initial opening into the masonry chimney select a brick that...

Page 9: ...ON CAUTION must be used when working on a roof Proper and safe scaffolding should be used for a safe installation of the Saf T Liner Always use a respirator and eye protection when using Saf T Wrap MA...

Page 10: ...p Plate supporting the upper sections of the liner system Slide the Rain Cap into the female portion of the Saf T Liner section and secure with the four self drilling screws provided See Figs 5 and 25...

Page 11: ...is not used the single wall connector pipe must be at least 18 from combustible construction material Clearances from the solid fuel burning appliances to combustible materials must be strictly adhere...

Page 12: ...y walls and cause cracking buckling distortion and or burnout in chimney liners A chimney liner damaged in such a way as to permit leakage of flue gases should be repaired or replaced Since there is a...

Page 13: ...workmanship For products installed after January 1 2009 for a period of Ten 10 years from original installation we will provide replacement product with a similar or like quality of available Selkirk...

Reviews: