ALCOVE
INSTALLATION
A
H
B
C
D
E
F
G
B
A
5
Framing and Clearances
A. Selecting Appliance Location
when selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
In addition to these framing dimensions, also reference the following sections:
• Clearances and Mantel Projections
(Sections 5.C, 5.D and 5.E)
• Vent Clearances and Framing
(Section 8).
CERONA-36
A
B
C
D
E
F
G
H
Inches
51
42-1/8 73-1/4
36
65-1/2
1/2
22-1/4
16
Millimeters
1295
1070
1861
914
1664
13
565
406
CERONA-42
A
B
C
D
E
F
G
H
Inches
56-5/8 49-1/8 80-1/8
36
72-1/2
1/2
22-1/4 18-3/4
Millimeters
1438
1248
2035
914
1842
13
565
476