SAFETY & CAUTION
• Instructions given in this manual and the applicable regulations of the local authorities
must be followed.
• The unit may be operated only by those persons who have been instructed in its proper use.
• The unit is to be installed and operated in such a way as to ensure the safety of employees and
surroundings.
• Never cover the unit’s air openings.
• Always ensure adequate fresh air supply to the unit.
• Never stand in front of the discharge end of the heater.
• Keep a minimum clearance of 10 feet from the fuel source. Storing and use of liquid fuel must
comply with the regulations and instructions given by the local authorities.
• Do not introduce foreign objects into the unit.
• Do not expose the unit to direct water jets.
• All electric cables outside the unit are to be protected against damage.
• Always disconnect the unit from power supply and turn off the gas supply when maintenance
or service is being performed.
•
IF NOT OPERATED WITHIN GUIDELINES OF THESE OPERATING INSTRUCTIONS,
MANUFACTURER WILL NOT BE HELD RESPONSIBLE AND WARRANTY
WILL BECOME VOID
.
3
SPECIFICATIONS
Model No. VG600
Fuels:
Vapor Propane or Natural Gas
Capacity:
600,000 BTU/HR
Blower:
5400 CFM
3/4” SP
Electrical Rating:
120 Volts, 15 Amps
Fuel Consumption:
NG-572 CFH / Propane-6.6 GPH
Gas Connection:
1” FNPT
Remote Thermostat:
On/Off
Max. Discharge Temp.:
175ºF @ 0ºF Ambient
Duct Size:
20” Dia., 75 ft. max (straight), temp. rating 225ºF min.
Actual Dimensions:
90”L x 36”W x 54”H
Weight (approximate):
770 lbs.
Utilize Dedicated 20 Amp Service
Gas Supply:
Inlet Pressure Manifold Pressure Burner Orifice
Max W.C.
Min W.C.
W.C.
Vapor Propane 14” W.C.
8” W.C.
2.8”
2.0
Natural Gas
14” W.C.
7” W.C.
2.8”
3.7
VF600
Fuel Supply:
Manifold Pressure (Fuel Pump) Burner Nozzle
151 psi
3.5 GPH x 60A
Note: 1 pound per square inch (psi) = 28” W.C. (water column)
Note: See page 14 for recommended duct, gas hose and pressure regulators.
Summary of Contents for VF600
Page 10: ...9 REFERENCE CHARTS ...
Page 11: ...10 Propane Orifice Kit PN BIE 3000886 Natural Gas Orifice PN BIE 3006703 ...
Page 13: ...WIRING CHART 12 ...
Page 14: ...13 PARTS BREAKDOWN ...
Page 16: ...15 SPARE PARTS BREAKDOWN VG900 VG600 VG700 ...
Page 18: ...17 RIELLO BURNER WIRING either 120V or 240V control systems ...
Page 19: ...18 RIELLO BURNER COMBUSTION HEAD ...
Page 20: ...19 RIELLO BURNER AIR GATE ...
Page 21: ...20 RIELLO BURNER COMBUSTION CHAMBER ...
Page 22: ...21 RIELLO BURNER START UP ...
Page 23: ...22 RIELLO BURNER DIAGNOSTICS ...
Page 24: ...23 RIELLO BURNER TROUBLESHOOTING ...
Page 25: ...VF600 OIL FIRED BURNER ELECTRODE SETTING 24 ...
Page 26: ...VF600 OIL FIRED BURNER AIR ADJUSTMENT 25 ...
Page 27: ...VF600 OIL FIRED BURNER PARTS BREAKDOWN 26 ...
Page 28: ...342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com ...