OPERATING INSTRUCTIONS
INSTALLATION
• When transporting, use both lifting eyes located on sides of heater.
• Place the unit on a level and non-combustible surface.
• Minimum clearances from combustibles:
- outlet, minimum 10 feet
- sides, minimum 3 feet
- top, minimum 3 feet
- flue pipe exhaust minimum 2 feet
• If the unit is placed indoors, secure an adequate fresh air opening for the burner combustion air.
• The unit may not be installed and operated in premises where explosive or combustible fumes
or dust are present. Always check the regulations of local authorities.
• Be certain that neither the air inlet nor the air outlet is obstructed.
FUEL SUPPLY
For supply pressures greater than 1/2psi
• A regulator must be installed on the heater to ensure that the pressure to the
heater does not exceed 1/2 psi inlet pressure. Excessive pressures over 1/2 psi
(14” W.C.) will damage controls and void warranty
.
• This heater is shipped as either natural gas or vapor propane. Check for proper burner orifice in
burner.
Vapor Propane
2.0
Natural Gas
3.7
• Be certain to use adequate hose or pipe size to ensure proper volume and pressure.
See Chart Below.
4
VAPOR PROPANE QUICK
REFERENCE HOSE
CHART
(Tank sizing chart
on page 9)
Hose
BTU
Length
600,000
in Feet 1/2PSI 10PSI
10
3/4
3/8
25
1
3/8
35
1
3/8
50
1-1/4 3/8
75
1-1/4 1/2
100
1-1/4 1/2
125
1-1/4 1/2
150
1-1/4 1/2
175
1-1/2 3/4
200
1-1/2 3/4
225
1-1/2 3/4
NATURAL GAS QUICK
REFERENCE HOSE
CHART
Hose
BTU
Length
600,000
in Feet 1/2PSI 1PSI 2PSI 5PSI
10
1
3/4
3/4
3/4
25
1-1/4 3/4
3/4
3/4
35
1-1/4 3/4
3/4
3/4
50
1-1/4 3/4
3/4
3/4
75
1-1/2 3/4
3/4
3/4
100
1-1/2 3/4
3/4
3/4
125
1-1/2
1
3/4
3/4
150
2
1
3/4
3/4
175
2
1-1/4
3/4
3/4
200
2
1-1/4
3/4
3/4
225
2
1-1/4
3/4
3/4
Summary of Contents for VF600
Page 10: ...9 REFERENCE CHARTS ...
Page 11: ...10 Propane Orifice Kit PN BIE 3000886 Natural Gas Orifice PN BIE 3006703 ...
Page 13: ...WIRING CHART 12 ...
Page 14: ...13 PARTS BREAKDOWN ...
Page 16: ...15 SPARE PARTS BREAKDOWN VG900 VG600 VG700 ...
Page 18: ...17 RIELLO BURNER WIRING either 120V or 240V control systems ...
Page 19: ...18 RIELLO BURNER COMBUSTION HEAD ...
Page 20: ...19 RIELLO BURNER AIR GATE ...
Page 21: ...20 RIELLO BURNER COMBUSTION CHAMBER ...
Page 22: ...21 RIELLO BURNER START UP ...
Page 23: ...22 RIELLO BURNER DIAGNOSTICS ...
Page 24: ...23 RIELLO BURNER TROUBLESHOOTING ...
Page 25: ...VF600 OIL FIRED BURNER ELECTRODE SETTING 24 ...
Page 26: ...VF600 OIL FIRED BURNER AIR ADJUSTMENT 25 ...
Page 27: ...VF600 OIL FIRED BURNER PARTS BREAKDOWN 26 ...
Page 28: ...342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com ...