28
Step 4. Positioning, Leveling, and
Securing the Fireplace
Place the fireplace into position.
Level the fireplace from side to side and from front to
back.
Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
Secure the fireplace to the framing by nailing or screwing.
!
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 29. Proper Positioning, Leveling, and
Securing of a Fireplace
Figure 30. Gas Control Systems
STANDING PILOT
Step 5. The Gas Control Systems
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with this model:
Standing Pilot Ignition
and
Direct Spark Ignition (DSI).
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING: 110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE IN A
MILLIVOLT SYSTEM.
!
WARNING: CONTINUOUS 110-120 VAC
SERVICE MUST BE WIRED DIRECTLY TO
THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM.
NOTE:
FLAMES TOO
CLOSE TO THE
CERAMIC INSULATORS
CAN CAUSE NUISANCE
LOCKOUTS AND
ELECTRODE FAILURE.
1/4" (6mm)
IGNITOR
3/8” (10mm)
CERAMIC
INSULATOR
DSI IGNITION
WARNING:
To ensure proper clearances
the front framing header
must be installed on its
narrow edge and to the
front of the frame.
Direct Spark Ignition (DSI) Sytem
This system includes a 120 VAC control valve, electronic
module and spark ignitor/flame sensor.