Heat-N-Glo ATS-AUST Installation And Operation Instruction Manual Download Page 20

19

CORRECTIVE ACTION

With the pilot in the ON position,
disconnect the thermopile leads
from the valve.  Take a reading
at the thermopile leads.  The
reading should be 325 millivolts
minimum.  Replace the thermo-
pile if the reading is below the
minimum.

1. Turn valve knob to “ON”. Place

ON/OFF switch to “ON”. Check
with millivolt meter at thermopile
terminals. Millivolt meter should
read greater than 100 m.v. If the
reading is okay and the burner
does not come on, replace the
gas valve.

1. Check burner orifice for stoppage

and remove.

1. Follow corrective action in A.1

above; check switch and wiring.
Replace where defective.

1. Clean and adjust pilot flame for

maximum flame impingement on

the  thermocouple.  Follow lighting

instruction carefully.

POSSIBLE CAUSE

C. Defective valve.

D. Plugged burner orifice.

E. Wall switch, or wires defective.

A.  Pilot flame may be too high or too

low, or blowing (high), causing pilot

safety to drop out.

SYMPTOM

V. Frequent pilot outage

problem.

Summary of Contents for ATS-AUST

Page 1: ...MN 55378 USA 612 890 8367 INSTALLATION AND OPERATION INSTRUCTIONS This product is covered by one or more of the following patents United States 4 112 913 4 408 594 4 422 426 4 424 792 4 520 791 4 793...

Page 2: ...be observed This appliance and it s components are tested and safe when installed in accor dance with this Installation Manual Report to your dealer any parts damaged in shipment specifically check g...

Page 3: ...7 Log Installation 11 1 8 Installer Testing 11 2 0 Operating Instructions 12 2 1 Safety and Lighting Information 13 2 2 Safety Information 13 2 3 Lighting Instructions 14 2 4 Fan Operation 15 3 0 Ser...

Page 4: ...3 FIGURE 1...

Page 5: ...CE OPENING WIDTH 32 1 8 816mm DEPTH 13 1 2 343mm HEIGHT 20 1 2 521mm NOTE If exhaust collar on insert and fireplace damper do not line up add 4 inches 102mm to minimum fireplace opening height to acco...

Page 6: ...F THE UNITANDTHE CENTER COLLAR OF THE TERMINATION CAP THE INLETAIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAROFTHEUNITAND ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP MODEL FLUE TE...

Page 7: ...6 FIGURE 4 FIGURE 5...

Page 8: ...r being siphoned from the outside of the building and all exhaust gases expelled to the outside of the build ing This model is designed to be installed in a ma sonry fireplace or factory built firepla...

Page 9: ...hold the collar bracket from sliding backwards Attach the pipe to cap adaptor to the termination cap and to the top of the flexible flue pipe and set the cap in place at the top of the chimney See Fi...

Page 10: ...1 4 FAN Model ATS AUST has a factory installed Fan Junction Box variable speed Rheostat Control Switch and Tem perature Sensor Switch for the fan The fan tempera ture sensor switch and junction box ar...

Page 11: ...ests against the log bracket at the left side of the firebox Drive a wood screw through this bracket and into log number 2 Step 3 Place Log Number 3 with it s flat side down between the rear log and t...

Page 12: ...leting the gas line connection a small amount of air will be in the lines When first lighting the pilot light it will take a few minutes for the lines to purge themselves of this air Once the purging...

Page 13: ...w minutes this moisture will disappear and within 15 30 minutes the flames should become yellow The heater may produce a noise caused from metal expansion and contraction as it heats up and cools down...

Page 14: ...t try to repair it Call a quali fied service technician Forced or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qua...

Page 15: ...ion turn the control knob counter clockwise to the Pilot position 7 Tolightthepilotdepressthecontrolknobandthen depress the red piezo button until it makes a clickingsound Itmaybenecessarytorepeatthis...

Page 16: ...NG Frequency of heater servic ing will depend upon use and type of installation B IMPORTANT TURN OFF GAS BEFORE SERVIC ING APPLIANCE IT IS RECOMMENDED THAT A COMPETENT SERVICE TECHNICIAN PERFORM SERVI...

Page 17: ...up and remove the log set log grate and refractory Unscrew the brackets at both ends of the burner and slide the burner to the right away from the burner orifice 2 Pilot Assembly Ignition System Remov...

Page 18: ...cted re place ignitor 1 Using a match light pilot If pi lot lights turn off pilot and trig ger the red button again If pilot lights an improper gas air mix ture caused the bad lighting and a longer pu...

Page 19: ...for proper connections Place jumper wires across terminals at switch if burner comes on re place defective switch If OK place jumper wires across switchwiresatgasvalve ifburner comes on wires are fau...

Page 20: ...read greater than 100 m v If the reading is okay and the burner does not come on replace the gas valve 1 Checkburner orificeforstoppage and remove 1 Follow corrective action in A 1 above check switch...

Page 21: ...rtain glass assembly is in stalled correctly and tighten cor ner 1 The horizontal flue cap should slope down only enough to pre vent any water from entering the unit The maximum downward slope is 1 4...

Page 22: ...isted in this manual may be ordered from an authorized dealer PART PART DESCRIPTION PART NUMBER Robertshaw Valve LP SRV60 522 Robertshaw Valve NG SRV60 523 Burner Orifice LP SRV57 801 Burner Orifice N...

Page 23: ...ONT PART PART DESCRIPTION PART NUMBER Glass Assembly SRV438 650A Glass Fastener Assembly SRV79 001A Piezo Ignitor SRV60 513 Thermopile SRV60 512 On Off Rotary Switch SRV436 525A Pilot Assembly LP SRV6...

Page 24: ...3 4 0 REPLACEMENT PARTS ATS AUST CONT PART PART DESCRIPTION PART NUMBER Refractory Base SRV438 700 Log Set Assembly SRV428 700A Dress Guard DF ATS AU Surround With Trim ATS AU 4028 Surround ATS AU 362...

Page 25: ...aleprice defectiveelectricalormanualcomponents optional componentsoraccessories andglasspanels notincludingglasspanelsbrokenduringmisuseorcareless handling HEAT N GLOshallnotberesponsibleforanylabor t...

Reviews: